J Korean Orthop Assoc.  2010 Apr;45(2):101-106. 10.4055/jkoa.2010.45.2.101.

Treatment of Unstable Intertrochanteric Fracture Using Short Barrel Compression Hip Screws and a Trochanteric Stabilizing Plate

Affiliations
  • 1Department of Orthopedic Surgery, SMG-SNU Boramae Medical Center, Seoul, Korea. ksyoon@brm.co.kr
  • 2Department of Orthopedic Surgery, Seoul National University Hospital, Seoul, Korea.

Abstract

PURPOSE
To assess the effectiveness of additional fixation using a trochanter stabilizing plate for the case of an unstable intertrochanteric fracture of the femur.
MATERIALS AND METHODS
Between February 2003 and February 2009, one hundred twenty-one consecutive patients with unstable intertrochanteric fractures were treated with CHSs and a TSP with or without additional screws and wiring. The follow up period was an average of twenty-eight months (range: six to sixty-one months). The fractures were classified according to the Jensen classification. We retrospectively evaluated the fracture healing time, the sliding length, the incidence of fixation failure and clinical failure, and the functional recovery.
RESULTS
The mean time to radiologic bony union was 16.2weeks. The average amount of lag screw sliding was 8.4 mm. Overall, 119 of 121 patients had bony union and 2 patients showed nonunion. Mechanical failure was noted in 5 patients and 8 patients showed clinical failure. Ninety-four patients (78%) had at least returned to their pre-fracture level of walking ability.
CONCLUSION
Fixation with compression hip screws (CHSs) and a trochanter stabilizing plate (TSP) for treating unstable intertrochanteric fracture of the femur seemed to be helpful for decreasing excessive sliding and the rate of fixation failure. Short barrel CHSs and TSP fixation with additional screws and wiring are necessary for treating unstable intertrochanteric fracture of the femur, and especially for the cases with a large posterior greater trochanteric fragment or a displaced lesser trochanter.

Keyword

femur; unstable intertrochanteric fracture; compression hip screw (CHS); trochanter stabilizing plate (TSP)

MeSH Terms

Femur
Follow-Up Studies
Fracture Healing
Hip
Hip Fractures
Humans
Incidence
Retrospective Studies
Walking

Figure

  • Figure 1 1A-D. A 68-year-old male underwent closed reduction and internal fixation using CHS and TSP with additional screw and wiring due to unstable intertrochanteric fracture. (A, B) Preoperative anteroposterior and lateral radiographs show three fragmentary fracture with displaced posterior greater trochanteric fragment (white arrow). (C) Six month follow-up anteroposterior radiograph and (D)11 month follow-up anteroposterior radiograph show cut-out of a lag screw.


Cited by  1 articles

Additional Fixations for Sliding Hip Screws in Treating Unstable Pertrochanteric Femoral Fractures (AO Type 31-A2): Short-Term Clinical Results
Su Hyun Cho, Soo Ho Lee, Hyung Lae Cho, Jung Hoei Ku, Jae Hyuk Choi, Alex J Lee
Clin Orthop Surg. 2011;3(2):107-113.    doi: 10.4055/cios.2011.3.2.107.


Reference

1. Forte ML, Virnig BA, Kane RL, et al. Geographic variation in device use for intertrochanteric hip fracture. J Bone Joint Surg Am. 2008. 90:691–699.
2. Flores LA, Harrington IJ, Heller M. The stability of intertrochanteric fractures treated with a sliding screw-plate. J Bone Joint Surg Br. 1990. 72:37–40.
Article
3. Karunaker M, Mclaurin TM, Morgan SJ, Egol KA. Improving outcomes after pertrochanteric hip fractures. Instr Course Lect. 2009. 58:91–104.
4. Den Hartog BD, Bartal E, Cooke F. Treatment of the unsatable intertrochanteric fractures. Effect of the placement of the screw, its angle of insertion, and osteotomy. J Bone Joint Surg Am. 1991. 73:726–733.
5. Min BW, Lee KJ. Treatment of intertrochanteric fracture: dynamic hip screw. J Korean Fract Soc. 2009. 22:51–55.
Article
6. Haidukewych GJ. Intertrichanteric fractures: Ten tips to improve results. J Bone Joint Surg Am. 2009. 91:712–719.
7. Babst R, Renner N, Biedermann M, et al. Clinical results using the trochanteric stabilizing plate (TSP): The modular extension of the dynamic hip screw (DHS) for internal fixation of selected unstable intertrochanteric fractures. J Orthop Trauma. 1998. 12:392–399.
8. Lee PC, Yu SW, Hsieh PH, Chuang TY, Tai CL, Shih CH. Treatment of early cut-out of a lag screw using a trochanter supporting plate: 11 consecutive patients with unstable intertrochanteric fractures. Arch Orthop Trauma Surg. 2004. 124:119–122.
Article
9. Gargan MF, Gundle R, Simpson AH. How effective are osteotomies for unstable intertrochanteric fractures? J Bone Joint Surg Br. 1994. 76:789–792.
Article
10. Kaufer H, Matthews LS, Sonstegard D. Stable fixation of intertrochanteric fractures. J Bone Joint Surg Am. 1974. 56:899–907.
Article
11. Davis TR, Sher JL, Horsman A, Simpson M, Poter BB, Checketts RG. Intertrochanteric femoral fractures: Mechanical failure after internal fixation. J Bone Joint Surg Br. 1990. 72:26–31.
Article
12. Baumgaertner MR, Solberg BD. Awareness of tip-apex distance reduces failure of fixation of trochanteric fractures of the hip. J Bone Joint Surg Br. 1997. 79:969–971.
Article
13. Kim YC, An KC, Kim KY, et al. Treatment of osteoporotic unstable intertrochanteric fracture-Comparative study between using dynamic hip screw and additional trochanter stabilizing plate-. J Korean Orthop Assoc. 2005. 40:741–748.
14. Kim YS, Kwon SY, Han SK, Choi WH, Choi NY. The role of lateral buttress in treatment of Jensen type 4 intertrochanteric fractures of the femur using dynamic compression hip screw in the elderly. J Korean Orthop Assoc. 2005. 40:935–941.
Article
15. Parker MJ, Palmer CR. A new mobility score for predicting mortality after hip fracture. J Bone Joint Surg Br. 1993. 75:797–798.
Article
16. Baixauli F, Vincent V, Baixauli E, et al. A Reinforced rigid fixation device for unstable intertrochanteric fractures. Clin Orthop Relat Res. 1999. 361:205–215.
Article
17. Gundle R, Gargan MF, Simpson AH. How to minimize failures of fixation of unstable intertrochanteric fractures. Injury. 1995. 26:611–614.
Article
18. Lorich DG, Geller DS, Nielson JH. Osteoporotic pertrochanteric hip fractures. Management and current controversies. Instr Course Lect. 2004. 53:441–454.
19. Evans EM. The treatment of trochanteric fractures of the femur. J Bone Joint Surg Br. 1949. 31:190–203.
Article
20. Jensen JS. Classificaiton of trochanteric fractures. Acta Orthop Scand. 1980. 51:803–810.
21. Boyd HB, Griffin LL. Classification and treatment of trochanteric fractures. Arch Surg. 1949. 58:853–863.
Article
22. Müller ME, Nazarian S. Classificaiton et documentation aoedes fractures femur. Rev Chir Orthop. 1981. 67:297.
23. Pervez H, Parker MJ, Vowler S. Prediction of fixation failure after sliding hip screw fixation. Injury. 2004. 35:994–998.
Article
24. Hardy DC, Descamps PY, Krallis P, et al. Use of an intramedullary hip-screw compared with a compression hip-screw with a plate for intertrochanteric femoral fractures. A prospective, randomized study of one hundred patients. J Bone Joint Surg Am. 1998. 80:618–630.
Article
25. Gotfried Y. The lateral trochanteric wall: a key element in the reconstruction of unstable pertrochanteric hip fractures. Clin Orthop Relat Res. 2004. 425:82–86.
26. Palm H, Jacobsen S, Holm SS, Gebuhr P. Hip Fracture Study Group. Integrity of the lateral femoral wall in intertrochanteric hip fractures: An important predictor of a reoperation. J Bone Joint Surg Am. 2007. 89:470–475.
27. Im GI, Shin YW, Song YJ. Potentially unstable intertrochanteric fractures. J Orthop Truma. 2005. 19:5–9.
Article
28. Chirodian N, Arch B, Parker MJ. Sliding hip screw fixation of trochanteric hip fractures: Outcome of 1024 procedures. Injury. 2005. 36:793–800.
Article
29. Bartonícek J, Fric V, Skála-Rosenbaum J, Dousa P. Avascular necrosis of the femoral head in pertrochanteric fractures: a report of 8 cases and review of the literature. J Orthop Trauma. 2007. 21:229–236.
30. Madsen JE, Naess L, Aune AK, Alho A, Ekeland A, Strømsøe K. Dynamic hip screw with trochanteric stabilizing plate in the treatment of the unstable proximal femoral fractures: a comparative study with the gamma nail and compression hip screw. J Orthop Trauma. 1998. 12:241–248.
Full Text Links
  • JKOA
Actions
Cited
CITED
export Copy
Close
Share
  • Twitter
  • Facebook
Similar articles