Korean J Thorac Cardiovasc Surg.  2016 Feb;49(1):35-38. 10.5090/kjtcs.2016.49.1.35.

Tricuspid Valve Re-Repair in Ebstein Anomaly Using the Cone Technique

Affiliations
  • 1Division of Cardiovascular Surgery, Department of Thoracic and Cardiovascular Surgery, Congenital Heart Disease Center, Severance Cardiovascular Hospital, Yonsei University College of Medicine, Korea. hank@yuhs.ac

Abstract

The management of recurrent tricuspid regurgitation after tricuspid valve repair in patients with Ebstein anomaly is difficult, and tricuspid valve replacement is most commonly performed in such patients. We report two cases of recurrent tricuspid regurgitation in patients with Ebstein anomaly that were successfully re-repaired using the cone technique. The cone repair technique is a useful surgical method for reconstructing a competent tricuspid valve, and can be applied in patients who have undergone previous tricuspid valve repair.

Keyword

Congenital heart disease; Tricuspid valve surgery; Repair; Ebstein anomaly

MeSH Terms

Ebstein Anomaly*
Heart Defects, Congenital
Humans
Tricuspid Valve Insufficiency
Tricuspid Valve*