1.Jemt T. Failures and complications in 391 consecutively inserted fixed prostheses supported by Brånemark implants in edentulous jaws: a study of treatment from the time of prosthesis placement to the first annual checkup. Int J Oral Maxillofac Implants. 1991. 6:270–6.
2.Schwarz MS. Mechanical complications of dental implants. Clin Oral Implants Res. 2000. 11:156–8.
Article
3.Jörnéus L., Jemt T., Carlsson L. Loads and designs of screw joints for single crowns supported by osseointegrated implants. Int J Oral Maxillofac Implants. 1992. 7:353–9.
4.Burguete RL., Johns RB., King T., Patterson EA. Tightening characteristics for screwed joints in osseointegrated dental implants. J Prosthet Dent. 1994. 71:592–9.
Article
5.Jaarda MJ., Razzoog ME., Gratton DG. Effect of preload torque on the ultimate tensile strength of implant prosthetic retaining screws. Implant Dent. 1994. 3:17–21.
Article
6.McGlumphy EA., Mendel DA., Holloway JA. Implant screw mechanics. Dent Clin North Am. 1998. 42:71–89.
7.McCracken MS., Mitchell L., Hegde R., Mavalli MD. Variability of mechanical torque-limiting devices in clinical service at a US dental school. J Prosthodont. 2010. 19:20–4.
Article
8.Cehreli MC., Akça K., Tönük E. Accuracy of a manual torque application device for morse-taper implants: a technical note. Int J Oral Maxillofac Implants. 2004. 19:743–8.
9.Tan KB., Nicholls JI. The effect of 3 torque delivery systems on gold screw preload at the gold cylinder-abutment screw joint. Int J Oral Maxillofac Implants. 2002. 17:175–83.
10.Standlee JP., Caputo AA., Chwu MY., Sun TT. Accuracy of mechanical torque-limiting devices for implants. Int J Oral Maxillofac Implants. 2002. 17:220–4.
11.Goheen KL., Vermilyea SG., Vossoughi J., Agar JR. Torque generated by handheld screwdrivers and mechanical torquing devices for osseointegrated implants. Int J Oral Maxillofac Implants. 1994. 9:149–55.
12.Gutierrez J., Nicholls JI., Libman WJ., Butson TJ. Accuracy of the implant torque wrench following time in clinical service. Int J Prosthodont. 1997. 10:562–7.
13.Vallee MC., Conrad HJ., Basu S., Seong WJ. Accuracy of friction-style and spring-style mechanical torque limiting devices for dental implants. J Prosthet Dent. 2008. 100:86–92.
Article
14.Joo YH., Lee JH. A study on accuracy and application of the implant torque controller used in dental clinic. J Korean Acad Prosthodont. 2011. 49:197–205.
Article
15.Sadr SJ., Fayyaz A., Mahshid M., Saboury A., Ansari G. Steam sterilization effect on the accuracy of friction-style mechanical torque limiting devices. Indian J Dent Res. 2014. 25:352–6.
Article
16.L'Homme-Langlois E., Yilmaz B., Chien HH., McGlumphy E. Accuracy of mechanical torque-limiting devices for dental implants. J Prosthet Dent. 2015. 114:524–8.
17.Cho LR., Park CJ., Huh YH., Lee JH., Kim DG. Comparative analysis of accuracy of how to use the implant torque controllers. J Korean Acad Prosthodont. 2013. 51:300–6.
Article