Korean J Thorac Cardiovasc Surg.  2005 May;38(5):389-391.

Venous Backflow in a Patent Polytetrafluoroethylene Arteriovenous Graft: A case report

Affiliations
  • 1Department of Thoracic and Cardiovascular Surgery, Hanyang University Guri Hospital, Korea. shchon@hanyang.ac.kr

Abstract

We report a case of a 48-year-old woman with end-stage renal failure who had a Polytetrafluoroethylene graft for hemodialysis and who had developed complications of venous outflow stenosis and venous backflow. Although venous backflow is an harbinger of graft failure, it is not enough reason to abandon the graft immediately. The patient was able to utilize her graft for 6 further months.

Keyword

Polytetrafluoroethylene; Arteriovenous shunt, Surgical; Shunts

MeSH Terms

Arteriovenous Shunt, Surgical
Constriction, Pathologic
Female
Humans
Kidney Failure, Chronic
Middle Aged
Polytetrafluoroethylene*
Renal Dialysis
Transplants*