J Korean Ophthalmol Soc.  2004 Jun;45(6):913-919.

The Efficacy and Safety of Dream Lens(TM) in School Children

Affiliations
  • 1Department of Ophthalmology, National Medical Center, Korea.
  • 2Vision Eye Center, #581-15 Sinsa-dong, Kangnam-ku, Seoul, Korea. damholee@unitel.co.kr
  • 3Department of Ophthalmology, Seoul National University Hospital, Korea.

Abstract

PURPOSE
This project was designed to study the effectiveness and safety of Dream lens(TM) (OK B+ series lenses, Contex, USA) in correcting myopia in a population of school children, under 13 years old. METHODS: Twenty-three school children aged 7 to 13 years followed over a 3-month period were fitted with lenses in the Vision Eye Center from September 2002 to March 2003. Slit lamp examination, uncorrected visual acuity, autorefraction and autokeratometry by Canon RK-5 and topography were measured at baseline and at 1week, 1 month, and 3 months after the lenses were worn. RESULTS: The mean baseline autorefraction was -2.54 +/- 1.00 diopters (range: -0.63~-4.00) and baseline uncorrected visual acuity over 0.5 was 11.1% and over 0.8 was 0%. Vision correction of over 0.8 was found in 80% of the cases in the first 1 week, 78% at 1 month, 91% at 3 months with the most rapid improvement occurring during the first 1 week. Superficial punctate keratitis occurred in 4 of 45 eyes, but there was no other pathologic problem. CONCLUSIONS: Dream lens is an effective and safe means of temporarily reducing myopia in a certain range of myopic patients; however, further studies are needed to determine the long-term effects on the eye health.

Keyword

Dream Lens; Effectiveness; Myopic correction; Safety

MeSH Terms

Adolescent
Child*
Humans
Keratitis
Myopia
Visual Acuity
Full Text Links
  • JKOS
Actions
Cited
CITED
export Copy
Close
Share
  • Twitter
  • Facebook
Similar articles
Copyright © 2024 by Korean Association of Medical Journal Editors. All rights reserved.     E-mail: koreamed@kamje.or.kr