J Korean Ophthalmol Soc.  1987 Aug;28(4):799-804.

AC/A Ratio Measured by Modified Gradient Method

Affiliations
  • 1Department of Ophthalmology, Yonsei University, College of Medicine, Seoul, Korea.

Abstract

A clinical study on the AC/A ratio with 125 normal persons was performed by modified gradient method. AC/A ratio is a convergence response of an individual to a unit stimulus of accommodation. Through many studies on the AC/A ratio, the normal range of the AC/A ratio was 3 delta/D ~ 5 delta/D. The AC/A ratio can be changed by some drugs. The AC/A ratio is high in divergence excessive exotropia, pseudodivergence exotropia and non-refractive accommodative esotropia; on the other hand, the AC/A ratio is low in convergence insufficiency exotropia. Methods for the determination of the AC/A ratio are heterophoria method, gradient method, fixation disparity method. This study was performed by modified gradient method due to easy application. The mean of the AC/A ratios in this study was 4.55 delta/D, and the AC/A ratios ranged from 0.5 delta/D to 9.6 delta/D. 95 percentile ranged from 3.01 delta/D to 6.09 delta/D. The AC/A ratio in this study seems not to be correlated with age, sex and interpupillary distance.


MeSH Terms

Esotropia
Exotropia
Hand
Humans
Ocular Motility Disorders
Reference Values
Vision Disparity
Full Text Links