J Korean Radiol Soc.  1998 Feb;38(2):229-232. 10.3348/jkrs.1998.38.2.229.

CT Findings of Orbital Blow-out Fracture

Affiliations
  • 1Department of Diagnostic Radiology, Chosun University College of Medicine.

Abstract

PURPOSE: To evaluate the usefulness and radiologic findings of CT in the diagnosis of orbital blow-outfracture.
MATERIALS AND METHODS
Forty-four patients with orbital blow-out fractures diagnosed by clinicalfindings and CT were evaluated retrospectively. On CT images, we evaluated the site and frequency of fracture,herniation of orbital fat, extraocular muscle abnormality, intraorbital hematoma, and intrasinus hemorrhage.
RESULTS
Forty-eight sites of orbital wall fractures were seen. Of these, 25(52.1%) were observed at the medialwall and 18(37.5%) at the inferior wall. Combined fracture of the medial and inferior wall was seen in fivecases(10.4%), and orbital fat herniation to adjacent sinuses in 25. Associated extraocular muscle abnormalitieswere seen at the medial rectus (n=20) and inferior rectus muscle(n=18). Intrasinus hemorrhage was seen in 15cases, and intraorbital hematoma in five.
CONCLUSION
CT is a useful diagnostic modality for the evaluation oforbital blow-out fracture and associated soft tissue abnormalities.

Keyword

Orbit, fractures; Orbit, CT

MeSH Terms

Diagnosis
Hematoma
Hemorrhage
Humans
Orbit*
Orbital Fractures*
Retrospective Studies
Full Text Links
  • JKRS
Actions
Cited
CITED
export Copy
Close
Share
  • Twitter
  • Facebook
Similar articles
Copyright © 2024 by Korean Association of Medical Journal Editors. All rights reserved.     E-mail: koreamed@kamje.or.kr