J Korean Shoulder Elbow Soc.  2009 Jun;12(1):1-6.

Mini-T Plate Fixation for Neer Type II Distal Clavicle Fracture

Affiliations
  • 1Department of Orthopedic Surgery, Sanggye Paik Hospital, School of Medicine, Inje Univ., Seoul, Korea. honeybud@empal.com

Abstract

PURPOSE: To evaluate and report the clinical and radiological outcomes of open reduction and internal fixation with a mini-T plate for unstable distal clavicle fractures.
MATERIALS AND METHODS
From December 2004 to July 2007, fifteen patients who had a fracture of the distal clavicle (Neer type II fracture) were treated with an open reduction and internal fixation using a mini-T plate. They were followed up for a minimum of one year and the clinical and radiological results were analyzed.
RESULTS
The average time to fracture union was 3.1(3~4) months. There were no complications, such as deep infection or fixation loss. The mean ASES score was 97 points (85~100points) at the last follow up period, and 14 patients had a full range of motion of the shoulder.
CONCLUSION
Open reduction and internal fixation with a mini-T plate for unstable distal clavicle fracture is a good surgical method with good clinical and radiological results.

Keyword

Distal clavicle; Fracture; Neer type II; Mini-T plate

MeSH Terms

Clavicle
Follow-Up Studies
Humans
Range of Motion, Articular
Shoulder
Full Text Links
  • JKSES
Actions
Cited
CITED
export Copy
Close
Share
  • Twitter
  • Facebook
Similar articles
Copyright © 2024 by Korean Association of Medical Journal Editors. All rights reserved.     E-mail: koreamed@kamje.or.kr