Korean Circ J.  1991 Oct;21(5):908-913. 10.4070/kcj.1991.21.5.908.

Transcatheter Double-Disc Occluder Closure of Patent Ductus Arteriosus

Abstract

We successfully closed the isolated patent ductusarteriosus(PDA) in 2 female patients using the Rashkind Double-Disc Occlusion system. nonsurgical closure of PDA usin plug was introduced by Porstmann in 1968 through transfemoral artery catheter and using umbrella by Rashkind in 1977 througth venous site. There has been continued improvement and simplification of the equipment as well as in the implantation technique. Nowaday, a multicenter study was conducted to test the safety and effectiveness of this interventioal method in States. Successful closure rate was high but some problems were reported such as embolization, abnormal deployment and residual shunt. Residual shunt was visualized by aortography in our both cases immediately after intervention but continuous murmur could not be heard in both cases. Oxygen step-up disappeared immediately after occluder implantation in both cases. Complete occlusion was expected with thrombus in near future.

Keyword

Patent ductus arteriosus; Double-disc occluder