Korean J Anesthesiol.  2005 Aug;49(2):152-156. 10.4097/kjae.2005.49.2.152.

Plasma Lidocaine Concentration and Hemodynamic Effect after 10% Lidocaine Spray on Laryngopharyngeal and Intratracheal Site during the Endotracheal Intubation

Affiliations
  • 1Department of Anesthesiology and Pain Medicine, College of Medicine, Hallym University, Seoul, Korea. kmshin1@yahoo.co.kr

Abstract

BACKGROUND: To minimize hemodynamic responses to laryngoscopy and endotracheal intubation, 10% lidocaine spray to laryngopharyngeal area seems to be favorable. The aim of this study was to evaluate plasma concentration and hemodynamic responses following different dose of 10% lidocaine spray before laryngoscopic intubation.
METHODS
Fifteen patients (ASA I, II) were randomly allocated. Group I (n = 5) patients were received saline spray for control, group II (n = 5) patients were received 1 mg/kg 10% lidocaine spray on laryngopharynx before induction of anesthesia and received 1 mg/kg 10% lidocaine topical spray to trachea under direct laryngoscopic view one minute before intubation, group III (n = 5) patients were received 1.5 mg/kg lidocaine spray. Hemodynamic response were measured at baseline, postspray 1 min, postintubation, postspray 2, 4, 6, 8, 10 min. Arterial blood samples for lidocaine concentration analysis were obtained at baseline and 2, 4, 6, 8, 10, 20, 30, 60, 120 minutes after larygopharyngeal and intratracheal administration of lidocaine.
RESULTS
The highest lidocaine concentrations in arterial blood were 1.76 +/- 0.52microgram/ml for group II, 2.86 +/- 0.40microgram/ml for group III (mean +/- SD) 2 to 10 minutes after laryngopharyngeal and intratracheal administration. There weren't any definitive toxic symptoms observed during the study. Hemodynamic responses of group II and III were not satisfactory but remarkably stable compared with group I. There were no differences between group II and III.
CONCLUSION
Sympathetic responses after 2-3 mg/kg lidocaine spray on laryngopharynx are favorably but not sufficiently attenuated during endotracheal intubation.

Keyword

laryngopharynx; lidocaine spray

MeSH Terms

Anesthesia
Hemodynamics*
Humans
Hypopharynx
Intubation
Intubation, Intratracheal*
Laryngoscopy
Lidocaine*
Plasma*
Trachea
Lidocaine
Full Text Links
  • KJAE
Actions
Cited
CITED
export Copy
Close
Share
  • Twitter
  • Facebook
Similar articles
Copyright © 2024 by Korean Association of Medical Journal Editors. All rights reserved.     E-mail: koreamed@kamje.or.kr