Korean J Anesthesiol.  1997 Jan;32(1):127-130. 10.4097/kjae.1997.32.1.127.

Airway Obstruction due to Mucous Plug During General Inhalation Anesthesia with Double Lumen Endobronchial Tube: A case report

Affiliations
  • 1Department of Anesthesia, Maryknoll Hospital, Pusan, Korea.
  • 2Department of Anesthesiology, Inha University College of Medicine, Incheon, Korea.
  • 3Department of Anesthesiology, Yonsei Cardiovascular Center and Research Institute, Yonsei University College of Medicine, Seoul, Korea.

Abstract

Acute airway obstruction during endotracheal anesthesia is embarrassing and critical situation which requires early diagnosis and immediate management. A 57-year-old man was scheduled for right pneumonectomy for a destroyed lung by fibroatelectatic changes and pleural calcification of right lung. We experienced high arterial PCO2 and inspiratory resistance during Left - Sided Double Lumen Endobronchial anesthesia in the left decubitus position. We exchanged tube after failure of suction and found airway obstruction due to mucous plug attached to the bevel of the endobronchial lumen.

Keyword

Airway mucous plug; obstruction; Anesthesia; general

MeSH Terms

Airway Obstruction*
Anesthesia
Anesthesia, Inhalation*
Early Diagnosis
Humans
Inhalation*
Lung
Middle Aged
Pneumonectomy
Suction