Korean J Anesthesiol.  2003 Dec;45(6):784-788. 10.4097/kjae.2003.45.6.784.

Anesthetic Management during Aortic Arch Surgery Using Anterograde Selective Cerebral Perfusion

Affiliations
  • 1Department of Anesthesiology and Pain Medicine, Seoul National University College of Medicine, Seoul, Korea.
  • 2Department of Thoracic Surgery, College of Medicine, Inje University, Korea.
  • 3Department of Anesthesiology and Pain Medicine, Hallym University College of Medicine, Seoul, Korea. noninvasive@hanmail.net

Abstract

Cerebral protection during aortic arch surgery is an anesthetic challenge, since the surgical procedures for aortic arch aneurysm involve an interruption of cerebral blood flow. We report a successfully managed case of aortic arch aneurysm repair with antegrade selective cerebral perfusion (SCP) during TCA (total circulatory arrest) using a transcranial oximeter, cerebral oxygenation was monitored during surgery. Although at the beginning of TCA a decrease in the regional cerebral oxygen saturation was observed, this was soon recovered by SCP. Except for the short period of TCA without SCP, regional cerebral oxygen saturation (rSO2) value were well maintained during surgery.

Keyword

cerebral protection; regional cerebral oxygen saturation (rSO2); selective antegrade cerebral perfusion (SCP); transcranial oximeter; total circulatory arrest (TCA)

MeSH Terms

Aneurysm
Aorta, Thoracic*
Oxygen
Perfusion*
Oxygen
Full Text Links
  • KJAE
Actions
Cited
CITED
export Copy
Close
Share
  • Twitter
  • Facebook
Similar articles
Copyright © 2024 by Korean Association of Medical Journal Editors. All rights reserved.     E-mail: koreamed@kamje.or.kr