Is small tidal volume with low positive end expiratory pressure during one-lung ventilation an effective ventilation method for endoscopic thoracic surgery?

Affiliations
  • 1Department of Anesthesiology and Pain Medicine, Ewha Womans University School of Medicine, Seoul, Korea. hanji@ewha.ac.kr

Abstract

BACKGROUND
The present study will focus on the rationale for the use of small tidal volume with 6 cmH2O positive end expiratory pressure (PEEP) with the changes of arterial oxygen tension, plateau airway pressure, and static lung compliance during one lung ventilation for endoscopic thoracic surgery.
METHODS
Forty-three patients were intubated with a double-lumen endobronchial tube. After positioning the patients in the lateral decubitus, one-lung ventilation was started with 100% oxygen, tidal volume 10 ml/kg without PEEP; arterial oxygen tension, plateau airway pressure, and static compliance were checked as baseline values (T0). Fifteen minutes later, same parameters were measured (T15). The tidal volume had changed to 6 ml/kg with 6 cmH2O PEEP. Fifteen minutes later, the same parameters were measured (T30).
RESULTS
Oxygen tension had decreased at T15 (282.1 +/- 83.4 mmHg) compared to T0 (477.2 +/- 82.4 mmHg) (P < 0.0001), but was maintained at T30 (270.4 +/- 81.9 mmHg). There was no difference in peak inspiratory pressure at T15 or T30 compared to T0, plateau airway pressure was increased at T15 and T30 (P < 0.05) and static lung compliance was decreased at T15 and T30 (P < 0.0001).
CONCLUSIONS
In carrying out one-lung ventilation for thoracic surgery using an endoscope, the addition of a PEEP of 6 cmH2O in the dependent lung, while reducing the tidal volume of 6 ml/kg, both oxygen tension and lung compliance are maintained without increasing the plateau airway pressure. Protective lung ventilation is useful for one lung ventilation.

Keyword

One-lung ventilation; Oxygenation; Positive-pressure respiration; Thoracoscopy; Tidal volume

MeSH Terms

Compliance
Endoscopes
Humans
Lung
Lung Compliance
One-Lung Ventilation*
Oxygen
Positive-Pressure Respiration*
Thoracic Surgery*
Thoracoscopy
Tidal Volume*
Ventilation*
Oxygen

Cited by  1 articles

Effects of small tidal volume and positive end-expiratory pressure on oxygenation in pressure-controlled ventilation-volume guaranteed mode during one-lung ventilation
Sung Hye Byun, So Young Lee, Jin Yong Jung
Yeungnam Univ J Med. 2018;35(2):165-170.    doi: 10.12701/yujm.2018.35.2.165.

Full Text Links
  • KJAE
Actions
Cited
CITED
export Copy
Close
Share
  • Twitter
  • Facebook
Similar articles
Copyright © 2024 by Korean Association of Medical Journal Editors. All rights reserved.     E-mail: koreamed@kamje.or.kr