Korean J Blood Transfus.  2014 Aug;25(2):105-112. 10.0000/kjbt.2014.25.2.105.

Evaluation of Point-of-Care Testing Devices for Pre-donation Alanine Aminotransferase Test

Affiliations
  • 1Blood Transfusion Research Institute, Korean Red Cross, Wonju, Korea. sykwon@redcross.or.kr
  • 2Seoul Dongbu Blood Center, Korean Red Cross, Seoul, Korea.
  • 3Blood Service Headquarters, Korean Red Cross, Wonju, Korea.

Abstract

BACKGROUND
In Korea, since 1990, in an effort to reduce the transmission of non-A, non-B hepatitis, all blood donations with alanine aminotransferase (ALT) levels above 65 IU/L are discarded. In 2012, 64.8% of the disposed blood units at the Korean Red Cross blood centers were due to high ALT levels. Pre-donation ALT testing might prevent unnecessary blood donation and save related expenses. We evaluated performance of point-of-care test (POCT) devices for pre-donation ALT screening.
METHODS
ALT levels by four ALT POCT devices (Mission C100, Acon; Reflotron Plus, Roche; Labgeo PT10, Samsung; and FDC NX500, Fujifilm) were compared with venous blood results using laboratory chemistry analyzers (AU series, Beckman Coulter Inc.). Intraclass correlation coefficients (ICCs), sensitivity (ability to detect ALT > or =65 IU/L), and specificity (ability to detect <65 IU/L) for each method were calculated.
RESULTS
Compared with the laboratory analyzers, the ICCs of ALT measurements by Mission C-100, Reflotron Plus, Labgeo PT10, and FDC NX500 were 0.96 (95% confidence interval (CI): 0.95~0.97), 0.99 (95% CI: 0.99~0.99), 0.98 (95% CI: 0.98~0.98), and 0.94 (95% CI: 0.91~0.96), respectively. The sensitivity was 80.95% for Mission C-100, 83.33% for Reflotron Plus, 78.57% for Labgeo PT10, and 97.62% for FDC NX500. The specificity was 99.13% for Mission C-100, 100.00% for Reflotron Plus, 99.78% for Labgeo PT10, and 98.26% for FDC NX500.
CONCLUSION
The ALT POCT devices showed almost perfect agreement with the laboratory analyzers and could be useful for pre-donation ALT screening. However, before implementing ALT POCT devices, cost-effectiveness analyses should be performed.

Keyword

Blood donation; Point-of-care test; Pre-donation ALT screening

MeSH Terms

Alanine Transaminase*
Blood Donors
Chemistry
Hepatitis
Humans
Korea
Mass Screening
Missions and Missionaries
Red Cross
Sensitivity and Specificity
Alanine Transaminase
Full Text Links
  • KJBT
Actions
Cited
CITED
export Copy
Close
Share
  • Twitter
  • Facebook
Similar articles
Copyright © 2024 by Korean Association of Medical Journal Editors. All rights reserved.     E-mail: koreamed@kamje.or.kr