J Korean Ophthalmol Soc.  2007 Jul;48(7):898-904.

The Potential Role of the Retinal Acuity Meter For Predicting Visual Outcome after Cataract Surgery

Affiliations
  • 1Department of Ophthalmology, Ilsan Paik Hospital, Inje University College of Medicine, Gyeonggi-do, Korea. dhlee@ilsanpaik.ac.kr
  • 2Department of Ophthalmology, Seoul Paik Hospital, College of Medicine, Inje University, Seoul, Korea.

Abstract

PURPOSE: To investigate the accuracy and usefulness of the retinal acuity meter (RAM) in predicting visual acuity after cataract surgery.
METHODS
We randomly selected 47 eyes from 43 patients who underwent cataract surgery in our clinic. Preoperative BCVA and 3 month postoperative BCVA were measured by the Snellen chart, and we recorded the preoperative visual acuity by RAM. We also grouped the patients according to diabetic retinopathy and preoperative BCVA 20/100. By comparing the expected visual acuity by RAM with actual postoperative BCVA values, we analyzed the accuracy of the RAM's predictability after surgery. The cataract types and macular disease were taken under consideration when analyzing our results.
RESULTS
Of the 47 eyes in our study, the postoperative Snellen visual acuity was predictable within three lines (90.9%) in 11 eyes with diabetic retinopathy and without macular disease. In the 36 eyes without diabetic retinopathy, the postoperative Snellen visual acuity was predictable within three lines (91.6%) of the cases. In both groups, the preoperative RAM acuity and postoperative BCVA were significantly correlated (R2=0.692, R2=0.812, p<0.05). In 41 eyes with preoperative BCVA 20/100 or more, the postoperative Snellen visual acuity was highly predictable in 95.1% (R2=0.763, p<0.05). However, in 6 eyes with preoperative BCVA levels less than 20/100, the postoperative Snellen visual acuity was not predictable (66.6 %). In the patients with both nucleosclerosis and posterior subcapsular opacity and in the patients with additional cortical opacity, the postoperative BCVA differed from the preoperative RAM acuity by more than three lines on the Snellen chart.
CONCLUSIONS
RAM is useful in predicting postoperative visual acuity in cataract patients, but may be unreliable in the patients with combined cataract forms or with preoperative BCVAs less than 20/100.

Keyword

Cataract type; Predictability; Retinal acuity meter

MeSH Terms

Cataract*
Diabetic Retinopathy
Humans
Retinaldehyde*
Visual Acuity
Retinaldehyde
Full Text Links
  • JKOS
Actions
Cited
CITED
export Copy
Close
Share
  • Twitter
  • Facebook
Similar articles
Copyright © 2024 by Korean Association of Medical Journal Editors. All rights reserved.     E-mail: koreamed@kamje.or.kr