J Korean Acad Prosthodont.  2005 Aug;43(4):453-465.

Accuracy of stone cast produced by adjustable dental impression tray

Affiliations
  • 1Department of Prosthodontics, School of Dentistry, Wonkwang University, Korea. scoh@wonkwang.ac.kr

Abstract

PURPOSE
This study was performed to measure the accuracy of adjustable dental impression trays by a scanning laser three-dimensional digitizer. MATERIALS AND METHODS: The metal stock, individual, and adjustable stock trays were used for 60 stone casts(10 casts each) duplicated a resin master model of mandible and maxilla. The type IV dental stone was poured in a vinyl polysiloxane impressions and allowed to set for one hour. The master model and the duplicated casts were digitized using an optical digitizer. The distance between the reference points were measured and analyzed on the graphic image of 3-D graphic software(CATIA version 5.0). The statistical significance of the differences between the groups was determined by a two-way ANOVA. RESULTS: There were no significant differences between the accuracies of the adjustable stock tray and the master model except only anterior arch width on the upper arch and the diagonal arch length and arch length on one side of the lower arch. CONCLUSION: The adjustable stock trays showed clinically acceptable accuracies of the study cast produced by them.

Keyword

Tray; Impression; Accuracy; Digitizer; Adjustable; Cast

MeSH Terms

Mandible
Maxilla
Siloxanes
Siloxanes
Full Text Links
  • JKAP
Actions
Cited
CITED
export Copy
Close
Share
  • Twitter
  • Facebook
Similar articles
Copyright © 2024 by Korean Association of Medical Journal Editors. All rights reserved.     E-mail: koreamed@kamje.or.kr