Korean J Anesthesiol.  2007 Mar;52(3):275-277. 10.4097/kjae.2007.52.3.275.

Appropriateness of Age-based Formula to Determine Endotracheal Tube Size in Korean Children

Affiliations
  • 1Department of Anesthesiology and Pain Medicine, Ilsan Hospital, College of Medicine, Dongguk University, Goyang, Korea. pissces@medimail.co.kr

Abstract

BACKGROUND
Age-based formulae have been widely used to predict appropriate size of the endotracheal tube (ETT) in children. The objective of this study was to evaluate the effectiveness of formula (internal diameter (ID) (mm) = [age in years + 16]/4) in Korean children.
METHODS
Ninety children under 8 years who required intubation with the regular uncuffed ETT were included in the study. Appropriate sizes were to permit a gas leak at 10-25 cmH2O with positive pressure ventilation. Initial intubation was tried with predetermined size and ETT was adjusted to meet this guideline.
RESULTS
A range of three tubes around the predicted tube size covered 79 cases (88%), whereas one size predicted by the formula applied to only 29 cases (32%). The selection of ETT which is 0.5 mm larger than the predicted size could allow appropriate intubation in 41 (45.6%) patients.
CONCLUSIONS
The age-based formula (ID (mm) = [age in years + 16]/4) could predict the appropriate tube size in less than one third our patients. Therefore, we recommend three sizes be available before endotracheal intubation.

Keyword

age-based formula; children; endotracheal tube

MeSH Terms

Child*
Humans
Intubation
Intubation, Intratracheal
Positive-Pressure Respiration
Full Text Links
  • KJAE
Actions
Cited
CITED
export Copy
Close
Share
  • Twitter
  • Facebook
Similar articles
Copyright © 2024 by Korean Association of Medical Journal Editors. All rights reserved.     E-mail: koreamed@kamje.or.kr