J Korean Radiol Soc.  2003 Sep;49(3):173-179. 10.3348/jkrs.2003.49.3.173.

Metallic Stent Implantation in Patients with Iliac Artery Occlusion: Long-term Patency Rate and Factors Related to Recurrence

Affiliations
  • 1Department of Diagnostic Radiology, Chonnam National University Hospital, School of Medicine. kjkrad@chonnam.ac.kr
  • 2Department of Surgery, Chonnam National University Hospital, School of Medicine.

Abstract

PURPOSE: To determine the long-term patency rate in 68 patients with iliac artery occlusion who underwent metallic stent implantation, and to analyze the factors related to recurrence.
MATERIALS AND METHODS
Sixty-eight patients with occlusive disease of the iliac artery underwent implantation of a self-expandable metallic stent. The clinical symptoms were intermittent claudication (n=48), resting pain (n=11), and gangrene (n=9). Stent patency was determined by follow-up angiography and color Doppler imaging, and the cumulative patency rate using the Kaplan-Meier method. Cox's proportional hazard model was used to analyse recurrence-related factors involving clinical symptoms (Fontaine stage), risk factors, and anatomical factors such as lesion location, length, and the development of collaterals. The duration of followup varied from 1 day to 73 months (mean, 23.8 months).
RESULTS
Arterial occlusion recurred in 16 of 68 patients (23.5%), and the cumulative patency rate was as follows: 95.4% at one month, 93.2% at six months, 80.1% at one year, 73.2% at two years, 68.9% at three years, and 62% at five years. According to a statistical analysis of risk factors, the recurrence p=0.04) than in those without it, but in patients who smoked, hypertension, DM, and previous cerebrovascular disease were not statistically significant. With regard to anatomical factors, the recurrent rate for lesions involving the external iliac artery was 6.5 times higher (p=0.02) than for those involving the common iliac artery. Variations in the Fontaine stage were not statistically significant indicators of recurrence.
CONCLUSION
The recurrence rate after implantation of an iliac artery stent is higher in patients with heart disease than in those without it, and higher for occlusive lesions involving the external iliac artery than for those of the common iliac artery.

Keyword

Arteries, iliac; Arteries, obstruction; Arteries, grafts and prosthesis; Percutaneous recanalization

MeSH Terms

Angiography
Follow-Up Studies
Gangrene
Heart Diseases
Humans
Hypertension
Iliac Artery*
Intermittent Claudication
Proportional Hazards Models
Recurrence*
Risk Factors
Smoke
Stents*
Smoke
Full Text Links
  • JKRS
Actions
Cited
CITED
export Copy
Close
Share
  • Twitter
  • Facebook
Similar articles