J Korean Soc Med Ultrasound.
2000 Mar;19(1):15-19.
Echogenic Rim of Hepatic Hemangioma on Abdominal Ultrasound
- Affiliations
-
- 1Department of Diagnostic Radiology, College of Medicine, Korea University.
Abstract
- PURPOSE
To investigate the association between the size of the hepatic hemangioma and the shape and thickness of the echogenic rim of hepatic hemangionma on abdominal ultrasound.
MATERIALS ADN METHODS: We examined 47 cases (M:F=24:23. mean age 47.1) of hepatic hemangiomas with e-chogenic rim on abdominal ultrasound during the past 2 years. Radiologic findings were retrospectively re-viewed in terms of completeness and thickness of echogenic rim. If echogenic rim showed even thickness, it was measured. But if not, the maximum and minimum thickness of the rim was measured. The association be-tween the size of hemangioma and the completeness and thickness of the echogenic rim were analyzed statisti-cally.
RESULTS
Of the 47 cases, complete echogenic rim and incomplete echogenic rim were obtained in 29 (62%) and 18 (38%) cases, respectively. Twenty-two cases of hemangioma were less than 2 cm in diameter, and their distri-bution according to echogenic rim were as follows: complete echogenic rim (17/20, 91% mean thickness 2.2 mm) and uneven thickness with complete echogenic rim (3/20, 15%, range:2.0 - 6.1 mm). Twenty-five he-mangiomas were larger than 2 cm in diameter and their distribution according to echogenic rim were as follows: complete echogenic rim (n=9, 34%), incomplete echogenic rim (n=16, 64%), even thickness with complete e-chogenic rim (3/9, 33%, mean thickness 2.2 mm) and uneven thickness with complete echogenic rim (6/9, 67%, range:2.0 - 7.6 mm). In statistical analysis, hemangiomas more than 2 cm in diameter were more likely to have incomplete echogenic rim (p<0.05) than those of less than 2 cm; hemangiomas more than with more than 2 cm in diameter and complete echogenic rim showed uneven thickne ss of echogenic rim (p<0.05), more often than those of less than 2 cm in diameter.
CONCLUSION
Hemangiomas with more than 2 cm in diameter showed more frequent incomplete echogenic rim than those of less than 2 cm in diameter, which had more frequent complete echogenic rim. Hemangiomas with complete echogenic rim and even rim thickness were more prevalent in those with less than 2 cm in diameter. Uneven rim thickness was present more often in those with more than 2 cm in diameter.