Korean Circ J.  1998 Mar;28(3):412-424. 10.4070/kcj.1998.28.3.412.

Respiratory Variations of Doppler Echocardiographic Parameters in Cardiac Tamponade

Abstract

BACKGROUND
Cardiac tamponade is associated with the expiratory increase and the expira-tory decrease in left ventricular filling flow. With Doppler echocardiography, we analyzed the respiratory variations of mitral and tricuspid inflows, and pulmonary and hepatic venous flows in patients with cardiac tamponade.
METHODS
Respiratory hemodynamic changes in mitral and tricuspid inflows and pulmonary and hepatic venous flows were evaluated using Doppler echocardiography in 13 patients (6 men and 7 women; mean age 51+/-13 years) with large pericardial effusion and clinical cardiac tamponade, and compared the results with those of 11 control subjects (3 men and 8 women, mean age 53+/-13 years). Doppler examination was repeated after pericardiocentesis in 6 patients.
RESULTS
Peak velocity of early diastolic mitral inflow (E velocity) decreased during inspiration compared with expiratory increase; the mean percentage change was 40%. Peak velocity of late diastolic mitral inflow (A velocity) decreased 13% during inspiration. E/A ratio decreased 31% during inspiration. Deceleration time (DT) and isovolumic relaxation time (IVRT) increased by 26% and 44%, respectively, during inspiration. But respiratory variations of tricuspid inflow were opposite to those of mitral inflow. Tricuspid E velocity increased during inspiration and decre-ased during expiration. The mean percentage change was 123%, which was larger than thte 40% of mitral inflow. The most characteristic findings of pulmonary venous flow during respiration were the expiratory increases of peak diastolic velocity (DV) and diastolic time-velocity integral (D-TVI). The mean percentage changes of peak systolic velocity (SV), DV and D-TVI during respiration were 27%, 45% and 53% respectively. In contrast, the SV and DV of hepatic venous flow increased during inspiration and decreased during expiration. The respiratory variations of peak systolic reverse flow velocity (SR) and peak diastolic reverse flow velocity (DR) were opposite to those of SV and DV. DR notably increased during expiration, and the mean percentage change was 61%. The ratio of RFI (Inspiratory reverse flow integral) to FFI (forward flow integral) of the tamponade group was 270%. The mean percentage changes of each parameters decreased after pericardiocentesis.
CONCLUSION
Patients with cardiac tamponade showed inspiratory increases of diastolic tri-cuspid filling flow and hepatic forward flow. Expiratory increases included diastolic mitral filling flow, pulmonary venous systolic and diastolic flow, and hepatic venous reverse flow. Such res-piratory variations decreased after pericardiocentesis.

Keyword

Cardiac tamponade; Doppler echocardiography; Respiratory cycle

MeSH Terms

Cardiac Tamponade*
Deceleration
Echocardiography*
Echocardiography, Doppler
Female
Hemodynamics
Humans
Male
Pericardial Effusion
Pericardiocentesis
Relaxation
Respiration
Full Text Links
  • KCJ
Actions
Cited
CITED
export Copy
Close
Share
  • Twitter
  • Facebook
Similar articles
Copyright © 2024 by Korean Association of Medical Journal Editors. All rights reserved.     E-mail: koreamed@kamje.or.kr