J Korean Radiol Soc.  1998 May;38(5):807-812. 10.3348/jkrs.1998.38.5.807.

Breath-Hold Gadolinium-enhanced MRA: Clinical Application

Affiliations
  • 1Department of Radiology, Inha University Hospital.

Abstract

PURPOSE: To compare breath-hold gadolinium enhanced MR angiography(MRA) with digital subtraction angiography.
MATERIALS AND METHODS
Ten patients underwent angiography and breath-hold gadolinium enhanced MRA;the latterperformed at 1.5T with 3D FSPGR after a bolus injection of gadopentetate dimeglumine(0.4mmol/kg)
RESULTS
Sevenof ten pathologic conditions(70%) evaluated by both techniques had a similar appearance. The conditions examinedwere as follows : the artery feeding renal cell carcinoma(n=2): renal artery stenosis(n=2); pulmonaryAVM(n=2);abdominal aortic aneurysm(n=1); atheromatous plaque in the lower abdominal aorta(n=1);an enlargedbronchial artery(n=1); and an aberrant renal artery(n=1). For evaluating an anatomic relationship, a reconstructed3D image obtained by MRA is more advantageous.
CONCLUSION
Breath hold contrast enhanced MRA is a potentiallyuseful noninvasive screening method for detecting vascular abnormality of the aorta and its branches.

Keyword

Angiography, comparative studies; Magnetic resonance(MR), comparative studies; Magnetic resonance(MR), vascularstudies

MeSH Terms

Angiography
Angiography, Digital Subtraction
Aorta
Arteries
Gadolinium
Humans
Mass Screening
Renal Artery
Gadolinium
Full Text Links
  • JKRS
Actions
Cited
CITED
export Copy
Close
Share
  • Twitter
  • Facebook
Similar articles
Copyright © 2024 by Korean Association of Medical Journal Editors. All rights reserved.     E-mail: koreamed@kamje.or.kr