Skip Navigation
Skip to contents

J Korean Soc Radiol.  2015 Jan;72(1):65-67. 10.3348/jksr.2015.72.1.65.

Retained Foreign Body in Pyothorax: Removal Using Snare Catheter and Endoscopic Biopsy Forcep Under the Fluoroscopic Guidance

Affiliations
  • 1Department of Radiology, Dongguk University Ilsan Hospital, Goyang, Korea. hanyoonhee@naver.com

Abstract

An iatrogenic foreign body (the surface coating polyurethane film of the guide wire) that was incurred during thoracentesis of chronic empyema, was removed by an interventional technique using a snare catheter and endoscopic biopsy forcep.


MeSH Terms

Biopsy*
Catheters*
Drainage
Empyema
Empyema, Pleural*
Foreign Bodies*
Pleural Cavity
Polyurethanes
SNARE Proteins*
Surgical Instruments*
Polyurethanes
SNARE Proteins
Full Text Links
  • JKSR
Actions
Cited
CITED
export Copy
Close
Share
  • Twitter
  • Facebook
Similar articles
Copyright © 2026 by Korean Association of Medical Journal Editors. All rights reserved.     E-mail: koreamed@kamje.or.kr