Long-Term Results of Total Hip Arthroplasty with an Extensively Porous Coated Stem in Patients Younger than 45 Years Old

Affiliations
  • 1Department of Orthopaedic Surgery, Inha University College of Medicine, Incheon, Korea. kangjoon@inha.ac.kr
  • 2Department of Orthopaedic Surgery, Cheju Universisity College of Medicine, Jeju, Korea.

Abstract

PURPOSE
This study analyzed the long-term results of cementless total hip arthroplasty using an extensively porous coated stem in patients younger than 45 years old. MATERIALS AND METHODS: The clinical and radiographic results of 45 hips from 38 patients who underwent cementless total hip replacement arthroplasty with an AML prosthesis were reviewed retrospectively. The average follow-up was 12 years (range, 10-15 years). RESULTS: The average Harris hip score at the time of final follow-up was 87.3 (range 77-94) points. Forty two hips (93.3%) showed excellent and good clinical results. Osteolysis occurred around the stem in 20 hips (44.4%) and around the cup in 26 hips (57.8%). Stress-mediated femoral resorption was observed in 33 hips (73.3%) at 10 years. There was no incidence of resorption progressing after 5 years postoperatively. There was no stem loosening. Five hips were revised for osteolysis, cup loosening and polyethylene wear. CONCLUSION: The long term results of total hip arthroplasty using an extensively porous coated stem were acceptable, and there was no case involving the progression of proximal bone resorption.

Keyword

Cementless total hip arthroplasty; extensively porous coated; polyethylene wear; osteolysis

MeSH Terms

Adult
Arthroplasty, Replacement, Hip/*adverse effects
Female
Hip Prosthesis/*adverse effects
Humans
Male
Osteolysis/etiology
Retrospective Studies
Treatment Outcome

Figure

  • Fig. 1 Radiography taken at postoperative 11 years shows osteolysis around cup with excessive polyethylene wear. Revision arthroplasty with an allograft was carried out for an osteolytic lesion.


Cited by  2 articles

Total Hip Arthroplasty Using AML® Prosthesis: Minimum 20-Year Follow-Up of the Patients
Chae-Hyun Lim, Young-Yool Chung, Dae-Hee Kim, Sang-Ho Ahn, Min-Yook Kim
J Korean Orthop Assoc. 2012;47(6):439-444.    doi: 10.4055/jkoa.2012.47.6.439.

Total Hip Arthroplasty Using AML® Prosthesis: Minimum 20-Year Follow-Up of the Patients
Chae-Hyun Lim, Young-Yool Chung, Dae-Hee Kim, Sang-Ho Ahn, Min-Yook Kim
J Korean Orthop Assoc. 2012;47(6):439-444.    doi: 10.4055/jkoa.2012.47.6.439.


Reference

1. Engh CA Sr, Fenwick JA. Extensively porous-coated stems: avoiding modularity. Orthopedics. 2008. 31:911–912.
Article
2. Engh CA, Bobyn JD. Biological fixation in total hip arthroplasty. 1985. USA: Slack;135–189.
3. Engh CA, Culpepper WJ II. Long-term results of use of the anatomic medullary locking prosthesis in total hip arthroplasty. J Bone Joint Surg Am. 1997. 79:177–184.
Article
4. Hastings DE, Tobin H, Sellenkowitsch M. Review of 10-year of results of PCA hip arthroplasty. Can J Surg. 1998. 41:48–52.
5. Kim YH, Kim VE. Cementless porous-coated anatomic medullary locking total hip prosthesis. J Arthroplasty. 1994. 9:243–252.
6. Bobyn JD, Glassman AH, Goto H, Krygier JJ, Miller JE, Brooks CE. The effect of stem stiffness on femoral bone resorption after canine porous-coated total hip arthroplasty. Clin Orthop Relat Res. 1990. 196–213.
Article
7. Claus AM, Hopper RH Jr, Engh CH. Fracture of the greater trochanter induced by osteolysis with the anatomic inedullary locking prosthesis. J Arthroplasty. 2002. 17:706–712.
Article
8. Engh CA, Bobyn JD. The influence of stem size and extent of porous coating on femoral bone resorption after primary cementless hip arthroplasty. Clin Orthop Relat Res. 1988. 7–28.
9. Engh CA, Bobyn JD, Glassman AH. Porous coated hip replacement. The factors governing bone ingrowth, stress shielding and clinical results. J Bone Joint Surg Br. 1987. 69:45–54.
10. Kröger H, Venesmaa P, Jurvelin J, Miettinen H, Suomalainen O, Alhava E. Bone density at the proximal femur after total hip arthroplasty. Clin Orthop Relat Res. 1998. 66–74.
11. Harris WH. Traumatic arthritis of the hip after dislocation and acetabular fracture: Treatment by mold arthroplasty. J Bone Joint Surg Am. 1969. 51:737–755.
Article
12. Gruen TA. Lemans JE, editor. Radiographic criteria for the clinical performance of uncemented total joint replacements . Quantitative characterization and performance of porous implants for hard tissue applications. . 1987. American society for Testing and Materials, Standards and Testing Protocols;207–218.
Article
13. Livermore J, Ilstrup D, Money B. Effect of femoral head size on wear of the polyethylene acetabular component. J Bone Joint Surg Am. 1990. 72:518–528.
Article
14. Kim YH, Oh JH, Oh SH. Cementless total hip arthroplasty in patients with osteonecrosis of the femoral head. Clin Orthop Relat Res. 1995. 73–84.
Article
15. Engh CA, Massin P, Suthers KE. Roentgenographic assessment of the biologic fixation of porous-surfaced femoral components. Clin Orthop Relat Res. 1990. 107–128.
Article
16. DeLee JG, Charnley J. Radiological demarcation of cemented sockets in total hip replacement. Clin Orthop Relat Res. 1976. 20–32.
Article
17. Schulte KR, Callaghan JJ, Kelley SS, Johnson RC. The outcome of Charnley total hip arthroplasty with cement after a minimum twenty-year follow-up. The results of one surgeon. J Bone Joint Surg Am. 1993. 75:961–975.
Article
18. Engh CA Jr, Young AM, Engh CA Sr, Hopper RH Jr. Clinical consequence of stress shielding after porous coated total hip arthroplasty. Clin Orthop Relat Res. 2003. 157–163.
Full Text Links
  • YMJ
Actions
Cited
CITED
export Copy
Close
Share
  • Twitter
  • Facebook
Similar articles
Copyright © 2024 by Korean Association of Medical Journal Editors. All rights reserved.     E-mail: koreamed@kamje.or.kr