Yonsei Med J.  2012 May;53(3):524-529. 10.3349/ymj.2012.53.3.524.

Comparison of Optical Coherence Tomographic Assessment between First- and Second-Generation Drug-Eluting Stents

Affiliations
  • 1Division of Cardiology, Severance Cardiovascular Hospital, Yonsei University College of Medicine, Seoul, Korea. mkhong61@yuhs.ac
  • 2Severance Biomedical Science Institute, Yonsei University College of Medicine, Seoul, Korea.

Abstract

PURPOSE
There is a lack of sufficient data in comparison of optical coherence tomographic (OCT) findings between first- and second-generation drug-eluting stents (DES). Compared to first-generation (i.e., sirolimus- or paclitaxel-eluting stents), second-generation DESs (i.e., everolimus- or biolinx-based zotarolimus-eluting stents) might have more favorable neointimal coverage.
MATERIALS AND METHODS
Follow-up OCT findings of 103 patients (119 lesions) treated with second-generation DESs were compared with those of 139 patients (149 lesions) treated with first-generation DESs. The percentage of uncovered or malapposed struts, calculated as the ratio of uncovered or malapposed struts to total struts in all OCT cross-sections, respectively, was compared between the two groups.
RESULTS
Both DES groups showed similar suppression of neointimal hyperplasia (NIH) on OCT (mean NIH cross-sectional area; second- vs. first-generation=1.1+/-0.5 versus 1.2+/-1.0 mm2, respectively, p=0.547). However, the percentage of uncovered struts of second-generation DESs was significantly smaller than that of first-generation DESs (3.8+/-4.8% vs.7.5+/-11.1%, respectively, p<0.001). The percentage of malapposed struts was also significantly smaller in second-generation DESs than in first-generation DESs (0.4+/-1.6% vs.1.4+/-3.7%, respectively, p=0.005). In addition, intra-stent thrombi were less frequently detected in second-generations DESs than in first-generation DESs (8% vs. 20%, respectively, p=0.004).
CONCLUSION
This follow-up OCT study showed that second-generation DESs characteristically had greater neointimal coverage than first-generation DESs.

Keyword

Optical coherence tomography; stent

MeSH Terms

Aged
Coronary Angiography
*Drug-Eluting Stents
Female
Humans
Male
Middle Aged
Neointima/pathology/prevention & control
Tomography, Optical Coherence/*methods

Cited by  1 articles

Stent Evaluation with Optical Coherence Tomography
Seung-Yul Lee, Myeong-Ki Hong
Yonsei Med J. 2013;54(5):1075-1083.    doi: 10.3349/ymj.2013.54.5.1075.


Reference

1. Moses JW, Leon MB, Popma JJ, Fitzgerald PJ, Holmes DR, O'Shaughnessy C, et al. Sirolimus-eluting stents versus standard stents in patients with stenosis in a native coronary artery. N Engl J Med. 2003. 349:1315–1323.
Article
2. Stone GW, Ellis SG, Cox DA, Hermiller J, O'Shaughnessy C, Mann JT, et al. A polymer-based, paclitaxel-eluting stent in patients with coronary artery disease. N Engl J Med. 2004. 350:221–231.
Article
3. Stone GW, Moses JW, Ellis SG, Schofer J, Dawkins KD, Morice MC, et al. Safety and efficacy of sirolimus- and paclitaxel-eluting coronary stents. N Engl J Med. 2007. 356:998–1008.
Article
4. Daemen J, Wenaweser P, Tsuchida K, Abrecht L, Vaina S, Morger C, et al. Early and late coronary stent thrombosis of sirolimus-eluting and paclitaxel-eluting stents in routine clinical practice: data from a large two-institutional cohort study. Lancet. 2007. 369:667–678.
Article
5. Stone GW, Midei M, Newman W, Sanz M, Hermiller JB, Williams J, et al. Comparison of an everolimus-eluting stent and a paclitaxel-eluting stent in patients with coronary artery disease: a randomized trial. JAMA. 2008. 299:1903–1913.
Article
6. Stone GW, Midei M, Newman W, Sanz M, Hermiller JB, Williams J, et al. Randomized comparison of everolimus-eluting and paclitaxel-eluting stents: two-year clinical follow-up from the Clinical Evaluation of the Xience V Everolimus Eluting Coronary Stent System in the Treatment of Patients with de novo Native Coronary Artery Lesions (SPIRIT) III trial. Circulation. 2009. 119:680–686.
Article
7. Meredith IT, Worthley S, Whitbourn R, Walters DL, McClean D, Horrigan M, et al. Clinical and angiographic results with the next-generation resolute stent system: a prospective, multicenter, first-in-human trial. JACC Cardiovasc Interv. 2009. 2:977–985.
Article
8. Mukherjee D, Moliterno DJ. Second-generation drug-eluting stents and the continuous need for rapidly available real-world data. JACC Cardiovasc Interv. 2009. 2:1236–1239.
Article
9. Meredith IT, Worthley SG, Whitbourn R, Walters D, McClean D, Ormiston J, et al. Long-term clinical outcomes with the next-generation Resolute Stent System: a report of the two-year follow-up from the RESOLUTE clinical trial. EuroIntervention. 2010. 5:692–697.
Article
10. Takano M, Inami S, Jang IK, Yamamoto M, Murakami D, Seimiya K, et al. Evaluation by optical coherence tomography of neointimal coverage of sirolimus-eluting stent three months after implantation. Am J Cardiol. 2007. 99:1033–1038.
Article
11. Guagliumi G, Sirbu V. Optical coherence tomography: high resolution intravascular imaging to evaluate vascular healing after coronary stenting. Catheter Cardiovasc Interv. 2008. 72:237–247.
Article
12. Kim U, Kim JS, Kim JS, Lee JM, Son JW, Kim J, et al. The initial extent of malapposition in ST-elevation myocardial infarction treated with drug-eluting stent: the usefulness of optical coherence tomography. Yonsei Med J. 2010. 51:332–338.
Article
13. Kim JS, Hong MK, Fan C, Kim TH, Shim JM, Park SM, et al. Intracoronary thrombus formation after drug-eluting stents implantation: optical coherence tomographic study. Am Heart J. 2010. 159:278–283.
Article
14. Barlis P, Dimopoulos K, Tanigawa J, Dzielicka E, Ferrante G, Del Furia F, et al. Quantitative analysis of intracoronary optical coherence tomography measurements of stent strut apposition and tissue coverage. Int J Cardiol. 2010. 141:151–156.
Article
15. Tanigawa J, Barlis P, Di Mario C. Intravascular optical coherence tomography: optimisation of image acquisition and quantitative assessment of stent strut apposition. EuroIntervention. 2007. 3:128–136.
16. Tanigawa J, Barlis P, Dimopoulos K, Dalby M, Moore P, Di Mario C. The influence of strut thickness and cell design on immediate apposition of drug-eluting stents assessed by optical coherence tomography. Int J Cardiol. 2009. 134:180–188.
Article
17. Joner M, Nakazawa G, Finn AV, Quee SC, Coleman L, Acampado E, et al. Endothelial cell recovery between comparator polymer-based drug-eluting stents. J Am Coll Cardiol. 2008. 52:333–342.
Article
18. Finn AV, Joner M, Nakazawa G, Kolodgie F, Newell J, John MC, et al. Pathological correlates of late drug-eluting stent thrombosis: strut coverage as a marker of endothelialization. Circulation. 2007. 115:2435–2441.
Article
19. Cook S, Wenaweser P, Togni M, Billinger M, Morger C, Seiler C, et al. Incomplete stent apposition and very late stent thrombosis after drug-eluting stent implantation. Circulation. 2007. 115:2426–2434.
Article
20. Hassan AK, Bergheanu SC, Stijnen T, van der Hoeven BL, Snoep JD, Plevier JW, et al. Late stent malapposition risk is higher after drug-eluting stent compared with bare-metal stent implantation and associates with late stent thrombosis. Eur Heart J. 2010. 31:1172–1180.
Article
21. Hong MK, Mintz GS, Lee CW, Park DW, Park KM, Lee BK, et al. Late stent malapposition after drug-eluting stent implantation: an intravascular ultrasound analysis with long-term follow-up. Circulation. 2006. 113:414–419.
Article
22. Kim JS, Jang IK, Kim JS, Kim TH, Takano M, Kume T, et al. Optical coherence tomography evaluation of zotarolimus-eluting stents at 9-month follow-up: comparison with sirolimus-eluting stents. Heart. 2009. 95:1907–1912.
Article
23. Kim BK, Ko YG, Oh S, Kim JS, Kang WC, Jeon DW, et al. Comparisons of the effects of stent eccentricity on the neointimal hyperplasia between sirolimus-eluting stent versus paclitaxel-eluting stent. Yonsei Med J. 2010. 51:823–831.
Article
24. Kim JS, Kim JS, Kim TH, Fan C, Lee JM, Kim W, et al. Comparison of neointimal coverage of sirolimus-eluting stents and paclitaxel-eluting stents using optical coherence tomography at 9 months after implantation. Circ J. 2010. 74:320–326.
Article
Full Text Links
  • YMJ
Actions
Cited
CITED
export Copy
Close
Share
  • Twitter
  • Facebook
Similar articles
Copyright © 2024 by Korean Association of Medical Journal Editors. All rights reserved.     E-mail: koreamed@kamje.or.kr