J Korean Fract Soc.  2015 Jan;28(1):46-52. 10.12671/jkfs.2015.28.1.46.

Treatment of Fractures of the Distal Radius Using Variable-Angle Volar Locking Plate

Affiliations
  • 1Department of Orthopedic Surgery, Sahmyook Medical Center, Seoul, Korea. crash1401@naver.com

Abstract

PURPOSE
The purpose of this study is to evaluate outcome of variable-angle volar locking plate for treatment of distal radius fractures.
MATERIALS AND METHODS
We retrospectively analyzed the results in 45 cases treated by variable-angle volar locking plate. We evaluated the clinical results according to the Mayo wrist performance scoring system and radiographic results.
RESULTS
All cases had bony union. The mean Mayo wrist performance scoring system was 84.8. Between preoperative and immediate postoperative radiographic measurement, the mean radial length improved from 8.4 to 11.8 mm, radial inclination from 14.2degrees to 22.4degrees, volar tilt from -4.5degrees to 9.6degrees, and intraarticular step-off from 1.8 to 0.3 mm (p<0.05). Between immediate postoperative and latest follow-up radiographic measurements, the mean loss of radial length measured 0.8 mm, radial inclination 0.4degrees, and volar tilt 0.9degrees (p>0.05). All cases showed bone union with no evidence of malunion, nonunion, or metal failure.
CONCLUSION
Treatment of distal radius fractures using variable angle volar locking plate showed satisfactory outcomes. It is a good option to obtain stable fixation without significant loss of reduction.

Keyword

Distal radius fracture; Volar approach; Variable angle volar locking plate

MeSH Terms

Follow-Up Studies
Radius Fractures
Radius*
Retrospective Studies
Wrist

Figure

  • Fig. 1 (A) A 40-year-old female patient presented with a distal radius fracture as AO classification C2. (B) Postoperative radiographs show acceptable reduction with variable angle volar locking compression plate. (C) Postoperative 12-month radiographs show complete bone union.


Reference

1. Moon ES, Kim MS, Kong IK. The amount and related factors of reduction loss in distal radius fracture after treatment by Kapandji technique. J Korean Fract Soc. 2007; 20:252–259.
Article
2. Cha SD, Park JH, Kim HS, et al. Comparative analysis of the results of fixed-angle versus variable-angle volar locking plate for distal radius fracture fixation. J Korean Fract Soc. 2012; 25:197–202.
Article
3. MacDermid JC, Roth JH, Richards RS. Pain and disability reported in the year following a distal radius fracture: a cohort study. BMC Musculoskelet Disord. 2003; 4:24.
Article
4. Papadonikolakis A, Shen J, Garrett JP, Davis SM, Ruch DS. The effect of increasing distraction on digital motion after external fixation of the wrist. J Hand Surg Am. 2005; 30:773–779.
Article
5. Leung F, Zhu L, Ho H, Lu WW, Chow SP. Palmar plate fixation of AO type C2 fracture of distal radius using a locking compression plate: a biomechanical study in a cadaveric model. J Hand Surg Br. 2003; 28:263–266.
Article
6. Trumble TE, Culp RW, Hanel DP, Geissler WB, Berger RA. Intra-articular fractures of the distal aspect of the radius. Instr Course Lect. 1999; 48:465–480.
7. Kamano M, Honda Y, Kazuki K, Yasuda M. Palmar plating for dorsally displaced fractures of the distal radius. Clin Orthop Relat Res. 2002; (397):403–408.
Article
8. Lipton HA, Wollstein R. Operative treatment of intraarticular distal radial fractures. Clin Orthop Relat Res. 1996; (327):110–124.
Article
9. Cho CH, Bae KC, Kwon DH. Volar T-locking compression plate for treatment of unstable distal radius fractures. J Korean Fract Soc. 2008; 21:220–224.
Article
10. Koval KJ, Hoehl JJ, Kummer FJ, Simon JA. Distal femoral fixation: a biomechanical comparison of the standard condylar buttress plate, a locked buttress plate, and the 95-degree blade plate. J Orthop Trauma. 1997; 11:521–524.
Article
11. Cooney WP, Bussey R, Dobyns JH, Linscheid RL. Difficult wrist fractures. Perilunate fracture-dislocations of the wrist. Clin Orthop Relat Res. 1987; (214):136–147.
12. Lim JY, Lee HY, Song JH, Kang JW, Lee JY. Evaluation of the reliability, construct validity, and responsiveness of the Korean version of the DASH. J Korean Soc Surg Hand. 2005; 10:192–198.
13. Choi JY, Kim KC, Kim KH. Analysis of result of operative treatment for distal radius fracture. J Korean Soc Fract. 2000; 13:338–342.
Article
14. Jupiter JB, Lipton H. The operative treatment of intraarticular fractures of the distal radius. Clin Orthop Relat Res. 1993; (292):48–61.
Article
15. Lee LW, Putnam MD. Unstable fractures of the distal radius: an algorithmic method of treatment. Orthop Trans. 1988; 12:357–541.
16. Choi WS, Kim WY, Choi DW, Shin YH, Kim JY. Anterior approach and volar T-plate fixation of distal radius fracture. J Korean Soc Fract. 2003; 16:244–252.
Article
17. Ha SS, Kim TH, Hong KD, Sim JC, Kim JH. Comparison of operative management in distal radius fractures using 3.5 mm versus 2.4 mm volar locking compression plates. J Korean Fract Soc. 2011; 24:156–162.
Article
18. Palmer AK, Werner FW. Biomechanics of the distal radioulnar joint. Clin Orthop Relat Res. 1984; (187):26–35.
Article
19. Herron M, Faraj A, Craigen MA. Dorsal plating for displaced intra-articular fractures of the distal radius. Injury. 2003; 34:497–502.
Article
20. Lowry KJ, Gainor BJ, Hoskins JS. Extensor tendon rupture secondary to the AO/ASIF titanium distal radius plate without associated plate failure: a case report. Am J Orthop (Belle Mead NJ). 2000; 29:789–791.
21. Harrison MR, Hamilton S, Johnstone AJ. Pseudo-rupture of Extensor Pollicis Longus following Kischner wire fixation of distal radius fractures. Acta Orthop Belg. 2004; 70:492–494.
22. Martineau PA, Berry GK, Harvey EJ. Plating for distal radius fractures. Orthop Clin North Am. 2007; 38:193–201.
Article
23. Rein S, Schikore H, Schneiders W, Amlang M, Zwipp H. Results of dorsal or volar plate fixation of AO type C3 distal radius fractures: a retrospective study. J Hand Surg Am. 2007; 32:954–961.
Article
24. Haidukewych GJ. Innovations in locking plate technology. J Am Acad Orthop Surg. 2004; 12:205–212.
Article
25. Perren SM. Evolution and rationale of locked internal fixator technology. Introductory remarks. Injury. 2001; 32:Suppl 2. B3–B9.
26. Park KC, Lee CH. Short term results of operative management with 2.4 mm volar locking compression plates in distal radius fractures. J Korean Fract Soc. 2009; 22:264–269.
Article
Full Text Links
  • JKFS
Actions
Cited
CITED
export Copy
Close
Share
  • Twitter
  • Facebook
Similar articles
Copyright © 2024 by Korean Association of Medical Journal Editors. All rights reserved.     E-mail: koreamed@kamje.or.kr