Korean J Ophthalmol.  1996 Jun;10(1):24-28. 10.3341/kjo.1996.10.1.24.

Relationship between optic nerve head parameters of Heidelberg Retina Tomograph and visual field defects in primary open-angle glaucoma

Affiliations
  • 1Department of Ophthalmology, College of Medicine, Seoul National University, Seoul, Korea.

Abstract

To investigate the correlation between optic nerve head configuration and visual field defects, optie nerve head analysis using confocal scanning laser tomography (Heidelberg Retina Tomograph, HRT) and automated static threshold perimetry using a Humphrey Field Analyzer (program C3O-2) were performed on 81 eyes of 44 primary open-angle glaucoma (POAG) patients. The optic nerve head parameters-rim area, rim volume, mean retinal nerve fiber layer thickness, height variation contour, and third moment in contour were measured by HRT and were analyzed for correlation with visual field indices-mean deviation, and corrected pattern standard deviation. All optic nerve hend parameters except HVC correlated significantly with the visual field indices; the highest correlation was between rim area and mean deviation (r = 0.6172, p < 0.O0001). The rim area of the superior and inferior quadrants correlated significantly with the visual field defects in corresponding sectors. Structural optic disc measurements by HRT correlated significantly with funetional optic nerve head damage in POAG

Keyword

HRT; optic nerve head parameters; visual field indices

MeSH Terms

Female
Glaucoma, Open-Angle/*pathology/physiopathology
Humans
Male
Middle Aged
Nerve Fibers/pathology
Optic Disk/*pathology/physiopathology
Retina/pathology
Tomography/*methods
Vision Disorders/*pathology/physiopathology
Visual Field Tests
*Visual Fields