Korean J Ophthalmol.  1990 Jun;4(1):16-22. 10.3341/kjo.1990.4.1.16.

Detection of early visual field change in ocular hypertension using STATPAC

Affiliations
  • 1Department of Ophthalmology, College of Medicine, Seoul National University, Seoul, Korea.
  • 2Glaucoma Service, Dr. Hong's Eye Clinic, Seoul, Korea.

Abstract

Perimetric tests were performed on 32 ocular hypertensive eyes (17 patients) with the C-30-2 threshold program of the Humphrey Visual Field Analyzer. The global indices of 32 ocular hypertensive eyes were compared with those of 34 normal eyes (17 controls). None of the 34 normal eyes had visual field sensitivity loss. However, three out of 32 ocular hypertensive eyes, which is 0.4%, had visual field sensitivity loss. Of these three eyes, two eyes showed generalized depression (MD, P < 5%) and one eye showed paracentral scotoma.

Keyword

ocular hypertensive eyes; Humphrey Visual Field Analyzer

MeSH Terms

Adolescent
Adult
Data Interpretation, Statistical
Humans
Intraocular Pressure
Middle Aged
Ocular Hypertension/*physiopathology
*Software
Visual Field Tests/*methods