J Korean Soc Parenter Enter Nutr.  2013 Apr;5(1):24-30.

A Comparison Between Measured and Predicted Resting Energy Expenditure of Pancreaticoduodenectomy Patients

Affiliations
  • 1Department of Surgery, Chonbuk National University Medical School, Jeonju, Korea. hcyu@jbnu.ac.kr
  • 2Nutrition Support Team, Chonbuk National University Hospital, Jeonju, Korea.
  • 3Biomedical Research Institute, Chonbuk National University Hospital, Jeonju, Korea.
  • 4Department of Food Science and Human Nutrition, Chonbuk National University, Jeonju, Korea.

Abstract

PURPOSE
An accurate determination of energy expenditure is needed to prevent postoperative complications and provide effective medical care for surgical patients. The aim of this study was to compare measured resting energy expenditure (REE) in patients undergoing pancreaticoduodenectomy (PD) using an indirect calorimetry (IC) with the help of five predictive equations.
METHODS
The subjects chosen for the study were 18 patients (12 males, 6 females) who underwent PD at Chonbuk National University Hospital between March 2010 and October 2011. REE was measured by IC (IC(REE)) and calculated with the following five predictive equations - ((eq)REE)-Harris-Benedict (HB), Mifflin St. Jeor (MI), American College of Chest Physician (AC), Ireton- Jones (IJ) and Cunningham (CU) equation - on postoperative day 3.
RESULTS
The mean measured REE by IC was 1,117.9+/-180.2, whereas the mean predicted REE by HB, MI, AC, IJ and CU equations were 1,241.3+/-156.1, 1,226+/-153.0, 1,401.7+/-188.0, 1,355.1+/-342.7, and 1,324.8+/-188.7 kcal/day, respectively. The mean predicted REE by HB, MI, AC, IJ, and CU were found to be significantly different from the measured ICREE. The intraclass correlation coefficient (ICC), which describes the degree of agreement with the IC(REE), was significantly highest in CU(eq)(REE) (r=0.679). The rate of accuracy of HB(eq)(REE), MI(eq)(REE), AC(eq)(REE), IJ(eq)(REE), and CU(eq)(REE) for IC(REE) was 27.8%, 50.0%, 27.8%, 22.2%, and 23.5%, respectively, in individual subjects.
CONCLUSION
The intraclass correlation coefficient (r=0.124~0.679) and accuracy rate (22.2~50.0%) determined from the results of REE measured by IC and that calculated by five predictive equations were low in overall. The low accuracy rate of energy expenditure by equations, which apply uniform indicators, can be explained by ongoing metabolic changes of the patient. Thus, the use of IC is recommended to assess energy requirements in PD; when this method is not practical in clinical settings, nutrition intervention is needed through regular monitoring because of the low accuracy rate of the predictive methods and IC(REE) that can cause inappropriate energy management, leading to metabolic disorders.

Keyword

Indirect calorimetry; Rest energy expenditure; Predictive energy expenditure; Equation

MeSH Terms

Calorimetry, Indirect
Energy Metabolism*
Humans
Jeollabuk-do
Male
Pancreaticoduodenectomy*
Postoperative Complications
Thorax
Full Text Links
  • JKSPEN
Actions
Cited
CITED
export Copy
Close
Share
  • Twitter
  • Facebook
Similar articles
Copyright © 2024 by Korean Association of Medical Journal Editors. All rights reserved.     E-mail: koreamed@kamje.or.kr