J Korean Assoc Maxillofac Plast Reconstr Surg.  2011 Sep;33(5):375-384.

Twisting Effect on Supermicroanastomosis of the Superficial Inferior Epigastric Artery in a Rat Model

Affiliations
  • 1Department of Oral and Maxillofacial Surgery, College of Dentistry, Seoul National University, Korea. smin5@snu.ac.kr

Abstract

PURPOSE
The advent of microsurgical technique and instruments, particularly in the field of perforator flap and supermicrosurgery, which have expanded the scope of microsurgery. However, supermicroanastomosis without any compression, tension, or distortions must be achieved to reach successful outcomes. Small-caliber vessels, such as those with an internal diameter less than 0.2 mm, are susceptible to inadvertent twisting of the anastomosis. In this study, using the superficial inferior epigastric artery (SIEA)-based flap model in Sprague-Dawley (SD) rats, we evaluated the acceptable limits of twisting effects on supermicroanastomotic sites.
METHODS
A total of 20 supermicroanastomoses were performed using the SIEA-based flap model in 10 male SD rats, 10-weeks-of-age, weighing 300~350 g. Rats were divided into five groups of two with four flaps as follows: 1) sham, 2) control group with end to end SIEA arterial supermicroanastomosis, 3) experimental I (EA1) with 90degrees twisting, 4) experimental II (EA2) with 180degrees twisting, and 5) experimental III (EA3) with 270degrees twisting of the supermicroanastomosis. Each SIEA was anastomosed using six 11-0 Ethilon(R) (Ethicon Inc. Co., NJ, USA) stitches except in the sham group where the SIEA was only clamped with Supermicro vascular clamps(R) (S&T, Neuhausen, Switzerland) for 20 minutes.
RESULTS
The anastomosed arterial patency showed no remarkable changes according to doppler waveforms measured with a Smardop 45 Doppler System (Hadeco Inc., Kawasaki, Japan). The pulsatility index (PI) was increased at postoperative day 10 in the EA2 and EA3 groups, and the resistance index (RI) showed no statistically significant difference between preoperative and postoperative values at 10 days. Histologic specimens from the EA3 group showed increased tunica media necrosis, convolution of the internal elastic lamina, densely packed platelets, fibrin, and erythrocytes. Flap viability and anastomosed vessel patency were not significantly affected by the degree of arterial twisting in this study, other than in the EA3 group where minor effects on arterial patency of the microanastomoses were encountered.
CONCLUSION
It appears that minor twisting on small caliber arteries, used in supermicroanastomoses, can be tolerated. However, twisting should be avoided as much as possible, and more than 180degrees twisting must be prevented in clinical practice.

Keyword

End to end anastomosis; Oral and maxillofacial reconstruction; Superficial inferior epigastric artery based flap; Supermicrosurgery; Twisting effect

MeSH Terms

Animals
Arteries
Blood Platelets
Epigastric Arteries
Erythrocytes
Fibrin
Glycosaminoglycans
Humans
Male
Microsurgery
Necrosis
Perforator Flap
Rats
Salicylamides
Tunica Media
Fibrin
Glycosaminoglycans
Salicylamides
Full Text Links
  • JKAMPRS
Actions
Cited
CITED
export Copy
Close
Share
  • Twitter
  • Facebook
Similar articles
Copyright © 2024 by Korean Association of Medical Journal Editors. All rights reserved.     E-mail: koreamed@kamje.or.kr