Yonsei Med J.  2012 Jul;53(4):794-800. 10.3349/ymj.2012.53.4.794.

Evaluation of Postoperative Range of Motion and Functional Outcomes after Cruciate-Retaining and Posterior-Stabilized High-Flexion Total Knee Arthroplasty

Affiliations
  • 1Department of Orthopaedic Surgery, Yonsei University College of Medicine, Seoul, Korea. cdhan@yuhs.ac

Abstract

PURPOSE
The purpose of this study was to compare postoperative range of motion and functional outcomes among patients who received high-flexion total knee arthroplasty using cruciate-retaining (CR-Flex) and posterior-stabilized (PS-Flex) type prostheses.
MATERIALS AND METHODS
Among 127 patients (186 knees) who underwent high-flexion total knee arthroplasty between 2005 and 2007, 92 knees were placed in the CR-Flex group, and 94 knees were placed in the PS-Flex group. After two years of postoperative follow-up, clinical and radiographic data were reviewed. Postoperative non-weight-bearing range of knee motion, angle of flexion contracture and functional outcomes based on the Western Ontario and McMaster Universities Osteoarthritis (WOMAC) functional sub-scale were assessed and compared between the two groups.
RESULTS
After the 2-year postoperative period, the mean range of motion was 131degrees in the CR-Flex group and 133degrees in the PS-Flex group. There were no significant differences in postoperative range of motion between the two groups. Only age at operation and preoperative range of motion were significantly associated with postoperative range of motion after high-flexion total knee arthroplasty. Postoperative functional outcomes based on the WOMAC functional sub-scale were slightly better in the CR-Flex group (9.2+/-9.1 points) than in the PS-Flex group (11.9+/-9.6 points); however, this difference was not statistically significant (p=non-significant).
CONCLUSION
The retention or substitution of the posterior cruciate ligament does not affect postoperative range of motion (ROM) or functional outcomes, according to 2 years of postoperative follow-up of high-flexion total knee arthroplasty.

Keyword

Total knee arthroplasty; range of motion; functional outcomes; cruciate-retaining; posterior-stabilized; high-flexion

MeSH Terms

Aged
Arthroplasty, Replacement, Knee/*methods
Female
Humans
Knee Prosthesis
Middle Aged
Posterior Cruciate Ligament/*surgery
Postoperative Period
Range of Motion, Articular/*physiology
Recovery of Function/physiology
Treatment Outcome

Reference

1. Kurosaka M, Yoshiya S, Mizuno K, Yamamoto T. Maximizing flexion after total knee arthroplasty: the need and the pitfalls. J Arthroplasty. 2002. 17:4 Suppl 1. 59–62.
Article
2. Harvey IA, Barry K, Kirby SP, Johnson R, Elloy MA. Factors affecting the range of movement of total knee arthroplasty. J Bone Joint Surg Br. 1993. 75:950–955.
Article
3. Schurman DJ, Matityahu A, Goodman SB, Maloney W, Woolson S, Shi H, et al. Prediction of postoperative knee flexion in Insall-Burstein II total knee arthroplasty. Clin Orthop Relat Res. 1998. 175–184.
Article
4. Ritter MA, Harty LD, Davis KE, Meding JB, Berend ME. Predicting range of motion after total knee arthroplasty. Clustering, log-linear regression, and regression tree analysis. J Bone Joint Surg Am. 2003. 85-A:1278–1285.
5. Sharma A, Komistek RD, Scuderi GR, Cates HE Jr. High-flexion TKA designs: what are their in vivo contact mechanics? Clin Orthop Relat Res. 2007. 464:117–126.
6. Seon JK, Park JK, Shin YJ, Seo HY, Lee KB, Song EK. Comparisons of kinematics and range of motion in high-flexion total knee arthroplasty: cruciate retaining vs. substituting designs. Knee Surg Sports Traumatol Arthrosc. 2011. 19:2016–2022.
Article
7. Cates HE, Komistek RD, Mahfouz MR, Schmidt MA, Anderle M. In vivo comparison of knee kinematics for subjects having either a posterior stabilized or cruciate retaining high-flexion total knee arthroplasty. J Arthroplasty. 2008. 23:1057–1067.
Article
8. Kim YH, Choi Y, Kwon OR, Kim JS. Functional outcome and range of motion of high-flexion posterior cruciate-retaining and high-flexion posterior cruciate-substituting total knee prostheses. A prospective, randomized study. J Bone Joint Surg Am. 2009. 91:753–760.
Article
9. Insall JN, Dorr LD, Scott RD, Scott WN. Rationale of the Knee Society clinical rating system. Clin Orthop Relat Res. 1989. 13–14.
Article
10. Insall JN, Ranawat CS, Aglietti P, Shine J. A comparison of four models of total knee-replacement prostheses. J Bone Joint Surg Am. 1976. 58:754–765.
Article
11. Bellamy N, Buchanan WW, Goldsmith CH, Campbell J, Stitt LW. Validation study of WOMAC: a health status instrument for measuring clinically important patient relevant outcomes to antirheumatic drug therapy in patients with osteoarthritis of the hip or knee. J Rheumatol. 1988. 15:1833–1840.
12. Ewald FC. The Knee Society total knee arthroplasty roentgenographic evaluation and scoring system. Clin Orthop Relat Res. 1989. 9–12.
Article
13. Figgie HE 3rd, Goldberg VM, Heiple KG, Moller HS 3rd, Gordon NH. The influence of tibial-patellofemoral location on function of the knee in patients with the posterior stabilized condylar knee prosthesis. J Bone Joint Surg Am. 1986. 68:1035–1040.
Article
14. Becker MW, Insall JN, Faris PM. Bilateral total knee arthroplasty. One cruciate retaining and one cruciate substituting. Clin Orthop Relat Res. 1991. 122–124.
15. Dorr LD, Ochsner JL, Gronley J, Perry J. Functional comparison of posterior cruciate-retained versus cruciate-sacrificed total knee arthroplasty. Clin Orthop Relat Res. 1988. 36–43.
16. Banks SA, Hodge WA. Accurate measurement of three-dimensional knee replacement kinematics using single-plane fluoroscopy. IEEE Trans Biomed Eng. 1996. 43:638–649.
Article
17. Dennis DA, Komistek RD, Hoff WA, Gabriel SM. In vivo knee kinematics derived using an inverse perspective technique. Clin Orthop Relat Res. 1996. 107–117.
Article
18. Banks SA, Markovich GD, Hodge WA. In vivo kinematics of cruciate-retaining and -substituting knee arthroplasties. J Arthroplasty. 1997. 12:297–304.
Article
19. Dennis DA, Komistek RD, Colwell CE Jr, Ranawat CS, Scott RD, Thornhill TS, et al. In vivo anteroposterior femorotibial translation of total knee arthroplasty: a multicenter analysis. Clin Orthop Relat Res. 1998. 47–57.
20. Haas BD, Komistek RD, Stiehl JB, Anderson DT, Northcut EJ. Kinematic comparison of posterior cruciate sacrifice versus substitution in a mobile bearing total knee arthroplasty. J Arthroplasty. 2002. 17:685–692.
Article
21. Dennis DA, Komistek RD, Mahfouz MR, Haas BD, Stiehl JB. Multicenter determination of in vivo kinematics after total knee arthroplasty. Clin Orthop Relat Res. 2003. 37–57.
22. Insall JN. Presidential address to The Knee Society. Choices and compromises in total knee arthroplasty. Clin Orthop Relat Res. 1988. 43–48.
23. Scott RD, Volatile TB. Twelve years' experience with posterior cruciate-retaining total knee arthroplasty. Clin Orthop Relat Res. 1986. 100–107.
Article
24. Maloney WJ, Schurman DJ. The effects of implant design on range of motion after total knee arthroplasty. Total condylar versus posterior stabilized total condylar designs. Clin Orthop Relat Res. 1992. 147–152.
25. Conditt MA, Noble PC, Bertolusso R, Woody J, Parsley BS. The PCL significantly affects the functional outcome of total knee arthroplasty. J Arthroplasty. 2004. 19:7 Suppl 2. 107–112.
Article
26. Insall JN, Hood RW, Flawn LB, Sullivan DJ. The total condylar knee prosthesis in gonarthrosis. A five to nine-year follow-up of the first one hundred consecutive replacements. J Bone Joint Surg Am. 1983. 65:619–628.
Article
27. Hirsch HS, Lotke PA, Morrison LD. The posterior cruciate ligament in total knee surgery. Save, sacrifice, or substitute? Clin Orthop Relat Res. 1994. 64–68.
28. Bertin KC, Komistek RD, Dennis DA, Hoff WA, Anderson DT, Langer T. In vivo determination of posterior femoral rollback for subjects having a NexGen posterior cruciate-retaining total knee arthroplasty. J Arthroplasty. 2002. 17:1040–1048.
Article
29. Tanzer M, Smith K, Burnett S. Posterior-stabilized versus cruciate-retaining total knee arthroplasty: balancing the gap. J Arthroplasty. 2002. 17:813–819.
30. Fuchs S, Tibesku CO, Frisse D, Genkinger M, Laass H, Rosenbaum D. Clinical and functional comparison of uni- and bicondylar sledge prostheses. Knee Surg Sports Traumatol Arthrosc. 2005. 13:197–202.
Article
31. Mihalko WM, Creek AT, Mary MN, Williams JL, Komatsu DE. Mechanoreceptors found in a posterior cruciate ligament from a well-functioning total knee arthroplasty retrieval. J Arthroplasty. 2011. 26:504.
Article
32. Dennis DA, Komistek RD, Stiehl JB, Walker SA, Dennis KN. Range of motion after total knee arthroplasty: the effect of implant design and weight-bearing conditions. J Arthroplasty. 1998. 13:748–752.
Article
Full Text Links
  • YMJ
Actions
Cited
CITED
export Copy
Close
Share
  • Twitter
  • Facebook
Similar articles
Copyright © 2024 by Korean Association of Medical Journal Editors. All rights reserved.     E-mail: koreamed@kamje.or.kr