J Korean Soc Med Ultrasound.  1999 Sep;18(3):187-192.

Comparison of Power Doppler and Color Doppler Ultrasonography in the Detection of Intratesticular Blood Flow of Normal Infants

Affiliations
  • 1Department of Radiology, Seoul Red Cross Hospital, Korea.

Abstract

PURPOSE: To Compare color Doppler ultrasonography (US) and power Doppler US in the detection of intratesticular blood flow in normal infants and to asses the symmetry of blood flow.
MATERIALS and METHODS
Testicular blood flow was assesed prospectively in 100 testes of 50 infants with both power and color Doppler US. We compared the power Doppler with color Doppler to detect intratesticular blood. When the flow was detected, intratesticular blood flow was graded as follows : grade 1 : single intratesticular Doppler signal; grade 2 : multiple intratesticular Doppler signals. The symmetry of intratesticular flow was assesd by using the same method.
RESULTS
Intratesticular flow was detected in 72 (72%) and 68 (68%) testes on power and color Doppler US, respectively. In 76 testes (76%), intratesticular flow was detected in either one or both techniques. On Power Doppler US, grade 1 was seen in 40 testes and grade 2 in 32 testes. On color Doppler US, grade 1 was noted in 52 testes and grade 2 in 16 testes. Testicular blood flow was symmetric on both power and color Doppler US in each patient.
CONCLUSION
There was no difference between power Doppler and color Doppler ultrasonography in detecting intratesticular blood flow in normal infants.


MeSH Terms

Equidae
Humans
Infant*
Prospective Studies
Testis
Ultrasonography, Doppler, Color*
Full Text Links
  • JKSMU
Actions
Cited
CITED
export Copy
Close
Share
  • Twitter
  • Facebook
Similar articles
Copyright © 2024 by Korean Association of Medical Journal Editors. All rights reserved.     E-mail: koreamed@kamje.or.kr