PURPOSE: Inferior blow-out fracture is the common facial fracture. Unsatisfactory functional and aesthetic outcomes are frequent when it is treated inappropriately. If fractures are extended and reach the posterior end of orbital floor, enophthalmos frequently followed as complication. The PURPOSE of this study was to evaluate reduction technique of extensive inferior blow-out fracture with ballooning of foley catheter through endoscopic transnasal approach and implantation of Medpor(R) through subciliary approach.
METHODS
A retrospective study was performed on 14 patients with extensive inferior blow-out fracture who underwent ballooning of foley catheter through endoscopic transnasal approach with implantation of Medpor(R) through subciliary approach. Patients were operated from May 2005 to November 2007. Data for 14 patients were acquired from patient's charts. Preoperative and postoperative data for enophthalmos, diplopia, limitation of extraocular motion were reviewed. Preoperative and postoperative CT scan were also checked. The patients were followed up from 4 to 18 months.
RESULTS
The enophthalmos was corrected in all patients. Among 7 patients with diplopia preoperatively, diplopia was resolved in three patients postoperatively. The diplopia persisted in four patients and two of them also had limitation of extraocular motion postoperatively. The limitation of extraocular motion occurred in seven patients preoperatively. But five patients recovered after operation immediately. These symptoms were resolved about three months after the operation.
CONCLUSION
The ballooning of foley catheter through endoscopic transnasal approach with implantation of Medpor(R) through subciliary approach can be considered one of the appropriate technique for extensive inferior blow- out fracture.

Keyword

Blow-out fracture; Orbital floor; Endoscopic

MeSH Terms

Catheters
Diplopia
Enophthalmos
Floors and Floorcoverings
Humans
Orbit
Orbital Fractures
Retrospective Studies
Full Text Links
  • JKCPCA
Actions
Cited
CITED
export Copy
Close
Share
  • Twitter
  • Facebook
Similar articles
Copyright © 2024 by Korean Association of Medical Journal Editors. All rights reserved.     E-mail: koreamed@kamje.or.kr