J Korean Hip Soc.  2009 Sep;21(3):232-237. 10.5371/jkhs.2009.21.3.232.

Total Hip Arthroplasty Using a Large Femoral Head: The Short-Term Follow-up Results and the Early Complications

Affiliations
  • 1Department of Orthopaedic Surgery, School of Medicine, Catholic University of Daegu, Daegu, Korea. cmr0426@cu.ac.kr

Abstract

PURPOSE
This study evaluated the short-term follow-up results after total hip arthroplasty with using a 36 mm large femoral head.
MATERIALS AND METHODS
Between August 2004 and August 2007, 104 patients were treated with total hip arthroplasties using a 36 mm-Cobalt-Chrome femoral head with Longevity (Zimmer, Warsaw, IN) as the polyethylene liner. The average age at the time of the index operation was 61.4 years (range: 23 to 87 years), and the mean follow-up period was 27 months (range: 18 to 46 months). The clinical results and early complications after the operation were analyzed.
RESULTS
The Harris Hip Scores were more than 'Good' in all cases with an average score of 93, and the Merle d' Aubigne and Postel scores were more than 'Good' in 75% of the patients. All the femoral stems that were cemented or cementless had satisfactory fixation. Dislocation developed in one case and only one time, and there were no other complications during the follow-up period
CONCLUSION
Total hip arthroplasty with using a 36 mm large femoral head is a recommendable treatment with a low dislocation rate and high satisfaction, which comes from the lack of restriction of the postoperative hip position and movement.

Keyword

Total hip arthroplasty; Large femoral head; HXLPE; Dislocation

MeSH Terms

Arthroplasty
Dislocations
Follow-Up Studies
Head
Hip
Humans
Longevity
Polyethylene
Polyethylene

Cited by  1 articles

Femoral Head Size of 36 mm against Highly Cross-linked Polyethylene in Patients Younger than 60 Years: Minimun Three Years of Follow Up
Chang-Min Park, Myung-Rae Cho, Shin-Kun Kim, Won-Kwon Choo, Jai-Bum Kwon
J Korean Orthop Assoc. 2012;47(1):28-34.    doi: 10.4055/jkoa.2012.47.1.28.

Full Text Links
  • JKHS
Actions
Cited
CITED
export Copy
Close
Share
  • Twitter
  • Facebook
Similar articles
Copyright © 2024 by Korean Association of Medical Journal Editors. All rights reserved.     E-mail: koreamed@kamje.or.kr