J Korean Hip Soc.  2010 Sep;22(3):189-196. 10.5371/jkhs.2010.22.3.189.

Revision Total Hip Arthroplasty Using a Fully Porous-Coated Long Stem: a Minimum 5 Years Follow up

Affiliations
  • 1Department of Orthopaedic Surgery, College of Medicine, Kyung Hee University, Seoul, Korea. yjcho@khmc.or.kr

Abstract

PURPOSE
We wanted to evaluate the mid-term results of revision total hip arthroplasty using a fully porous-coated long stem.
MATERIALS AND METHODS
A retrospective series of 20 hips in 19 patients who underwent stem revision with a fully porous-coated long stem were evaluated at a mean follow-up of 64.6 months. The causes of revision were aseptic loosening, periprosthetic fracture and infected arthroplasty. Four kinds of implants had previously been used and an additional bone graft procedure had been done in 17 cases. The Harris hip scores, thigh pain, limping and ROM were reported. Radiological changes of the radiolucent signs, subsidence, loosening and the stress shielding signs were evaluated.
RESULTS
The Harris hip score improved from an average of 56.5 to 91.9 and the ROMs were satisfactory. The only case with persistent thigh pain showed stable bony ingrowth. No signs of subsidence or loosening of the stem was found in all the cases. There were 2 cases of periprosthetic fracture. None of the patients experienced re-revision surgery.
CONCLUSION
The mid-term results of revision hip arthroplasty using a fully porous coated long stem have demonstrated that it provides a reliable initial fixation with a propensity for stable longevity. It is relatively easy for the techniques, and there is the opportunity to restore the bone stock by bone-grafting procedures with diaphyseal fixation and bypassing a bone defect. Yet alternative techniques may be required for the femur with extensive diaphyseal bone loss. There are some concerns about the technique and the possibility of making a crack in the femur during the operation, which will cause thigh pain at the follow-up. So, only by employing great caution when performing this technique can successful results be guaranteed.

Keyword

Femur; Osteolysis; Revision total hip arthroplasty; Fully porous coated long stem

MeSH Terms

Arthroplasty
Femur
Follow-Up Studies
Hip
Humans
Longevity
Osteolysis
Periprosthetic Fractures
Retrospective Studies
Thigh
Transplants

Figure

  • Fig. 1 (A) 35-year-old female with Paprosky type IIIA bone defect in her left femur showed significant loosening of the primary cemented stem. (B) The hip was revised using Versys™ (Zimmer, U.S.A.) 200 mm stem and impaction morselized allograft with wire mesh support. We used wire fixation for the extended trochanteric osteotomy area. (C) 68-month after revision surgery, it showed stable bony ingrowth at diaphysis with successful consolidation and remodeling of allograft.

  • Fig. 2 35-year-old male. (A) A cemented stem was placed into a femur with a Paprosky type IIIA bone defect. Bone loss of the greater trochanter, perforated by loosening stem, is shown in the anteroposterior preoperative radiograph. (B) The hip was revised with Versys™ (Zimmer, U.S.A.) 200 mm stem. Bony supporting with strut allograft and impaction morselized allograft was done. (C) 68-month after revision surgery, radiograph revealed a sign of stable bony ingrowth at diaphyseal area with a sign of allograft consolidation. The patient experienced a mild thigh pain with irritation pain at greater trochanteric area.

  • Fig. 3 40-year-old male. (A) His right femur was under the state of 10-year-after PROSTALAC insertion due to the infection primary total hip arthroplasty. It showed aseptic loosening and Paprosky type IIIB bone loss. (B) His femur has revised using Versys™ (Zimmer, U.S.A.) 200 mm stem with strut allograft to made up proximal bony support. (C) 72-month from the surgery, we could not find any evidence of micro-motion or implant loosening. It showed stable bony ingrowth fixation with partial allograft absorption. He has complained persistent mild thigh pain.

  • Fig. 4 Post-operative changes of the range of motion.


Reference

1. Della Valle CJ, Paprosky WG. The femur in revision total hip arthroplasty evaluation and classification. Clin Orthop Relat Res. 2004. 420:55–62.
Article
2. Mulroy WF, Harris WH. Revision total hip arthroplasty with use of so-called second-generation cementing techniques for aseptic loosening of the femoral component. A fifteen-year-average follow-up study. J Bone Joint Surg Am. 1996. 78:325–330.
Article
3. Pellicci PM, Wilson PD Jr, Sledge CB, et al. Long-term results of revision total hip replacement. A follow-up report. J Bone Joint Surg Am. 1985. 67:513–516.
Article
4. Paprosky WG, Greidanus NV, Antoniou J. Minimum 10-year results of extensively porous-coated stems in revision hip arthroplasty. Clin Orthop Relat Res. 1999. 369:230–242.
Article
5. Weeden SH, Paprosky WG. Minimal 11-year follow-up of extensively porous-coated stems in femoral revision total hip arthroplasty. J Arthroplasty. 2002. 17:Suppl. 134–137.
Article
6. Callaghan JJ, Salvati EA, Pellicci PM, Wilson PD Jr, Ranawat CS. Results of revision for mechanical failure after cemented total hip replacement, 1979 to 1982. A two to five-year follow-up. J Bone Joint Surg Am. 1985. 67:1074–1085.
Article
7. Gie GA, Linder L, Ling RS, Simon JP, Slooff TJ, Timperley AJ. Contained morselized allograft in revision total hip arthroplasty. Surgical technique. Orthop Clin North Am. 1993. 24:717–725.
8. Sporer SM, Paprosky WG. Revision total hip arthroplasty: the limits of fully coated stems. Clin Orthop Relat Res. 2003. 417:203–209.
9. Buttaro MA, Mayor MB, Van Citters D, Piccaluga F. Fatigue fracture of a proximally modular, distally tapered fluted implant with diaphyseal fixation. J Arthroplasty. 2007. 22:780–783.
Article
10. Kim YH. Cemented revision hip arthroplasty using strut and impacted cancellous allografts. J Arthroplasty. 2004. 19:726–732.
Article
11. Oakes DA, Cabanela ME. Impaction bone grafting for revision hip arthroplasty: biology and clinical applications. J Am Acad Orthop Surg. 2006. 14:620–628.
Article
12. Schreurs BW, Arts JJ, Verdonschot N, Buma P, Slooff TJ, Gardeniers JW. Femoral component revision with use of impaction bone-grafting and a cemented polished stem. Surgical technique. J Bone Joint Surg Am. 2006. 88:Suppl. 259–274.
Article
13. Sierra RJ, Charity J, Tsiridis E, Timperley JA, Gie GA. The use of long cemented stems for femoral impaction grafting in revision total hip arthroplasty. J Bone Joint Surg Am. 2008. 90:1330–1336.
Article
14. Blackley HR, Davis AM, Hutchison CR, Gross AE. Proximal femoral allografts for reconstruction of bone stock in revision arthroplasty of the hip. A nine to fifteen-year follow-up. J Bone Joint Surg Am. 2001. 83:346–354.
Article
15. Gross AE, Hutchison CR. Proximal femoral allografts for reconstruction of bone stock in revision arthroplasty of the hip. Orthop Clin North Am. 1998. 29:313–317.
Article
16. Haentjens P, De Boeck H, Opdecam P. Proximal femoral replacement prosthesis for salvage of failed hip arthroplasty: complications in a 2-11 year follow-up study in 19 elderly patients. Acta Orthop Scand. 1996. 67:37–42.
Article
17. Parvizi J, Sim FH. Proximal femoral replacements with megaprostheses. Clin Orthop Relat Res. 2004. 420:169–175.
Article
18. Moreland JR, Bernstein ML. Femoral revision hip arthroplasty with uncemented, porous-coated stems. Clin Orthop Relat Res. 1995. 319:141–150.
Article
19. Gustilo RB, Bechtold JE, Giacchetto J, Kyle RF. Rationale, experience and results of long-stem femoral prosthesis. Clin Orthop Relat Res. 1989. 249:159–168.
Article
20. Ornstein E, Atroshi I, Franzén H, Johnsson R, Sandquist P, Sundberg M. Results of hip revision using the Exeter stem, impacted allograft bone, and cement. Clin Orthop Relat Res. 2001. 389:126–133.
Article
21. Hellman EJ, Capello WN, Feinberg JR. Nonunion of extended trochanteric osteotomies in impaction grafting femoral revisions. J Arthroplasty. 1998. 13:945–949.
Article
22. Höstner J, Hultmark P, Kärrholm J, Malchau H, Tveit M. Impaction technique and graft treatment in revisions of the femoral component: laboratory studies and clinical validation. J Arthroplasty. 2001. 16:76–82.
Article
23. Engh CA, Massin P, Suthers KE. Roentgenographic assessment of the biologic fixation of porous-surfaced femoral components. Clin Orthop Relat Res. 1990. 259:107–128.
Article
24. Krishnamurthy AB, MacDonald SJ, Paprosky WG. 5- to 13-year follow-up study on cementless femoral components in revision surgery. J Arthroplasty. 1997. 12:839–847.
Article
Full Text Links
  • JKHS
Actions
Cited
CITED
export Copy
Close
Share
  • Twitter
  • Facebook
Similar articles
Copyright © 2024 by Korean Association of Medical Journal Editors. All rights reserved.     E-mail: koreamed@kamje.or.kr