J Korean Med Sci.  1986 Sep;1(1):59-62. 10.3346/jkms.1986.1.1.59.

A representative value for 24-hour monitored ambulatory blood pressure

Affiliations
  • 1Department of Internal Medicine, INJE Medical College, Park Hospital, Seoul, Korea.

Abstract

Several shorter-term alternatives for whole-day ambulatory monitoring of blood pressure using Pressurometer III or conventional sphygmomanometer were evaluated in 12 male patients with mild hypertension. Averages of BP reading at 8 AM once, 3 consecutive-readings either with Pressurometer or manually, serial readings for 2-hour intervals from 8-10 AM and 2-4 PM were compared with that of 24-hour ambulatory, non-invasive BP readings by Pressurometer. Both systolic and diastolic 2-hour BP averages in the morning (8 to 10 o'clock) correlated more strongly with 24-hour averages (r = 0.91 and 0.91) than the 3 consecutive (r = 0.88 and 0.66) or single (r = 0.49 and -0.35) reading alternatives did. In conclusion, the average of serial readings obtained during 2-hour monitoring period from 8 to 10 AM is a reliable predictor of 24-hour ambulatory BP and represents it more closely than the conventional single or multiple BP readings.

Keyword

Blood pressure Ambulatory

MeSH Terms

*Blood Pressure
Blood Pressure Determination
Blood Pressure Monitors
Humans
Male
Time Factors
Full Text Links
  • JKMS
Actions
Cited
CITED
export Copy
Close
Share
  • Twitter
  • Facebook
Similar articles