Mini ongoing implant to replace anterior single missing tooth with limited space: A clinical report

Kim JW, Bae HE, Hwang S

  • KMID: 2000729
  • J Korean Acad Prosthodont.
  • 2005 Jun;43(3):331-337.
For a missing teeth, orthodontic treatment may be a better choice of treatment in comparison to a conventional prosthetic replacement such as FPD, resin bonded prosthesis in view of aesthetics,...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
The effect of surface finishes on flexural strength, fracture toughness of feldspathic dental porcelain

Chang IS, Lee SH, Yang JH, Han JS, Lee JB

  • KMID: 2000725
  • J Korean Acad Prosthodont.
  • 2005 Jun;43(3):293-305.
STATEMENT OF PROBLEMS: Conventional feldspathic porcelain is used extensively as a restorative material and it is subjected to grinding and polishing during fabrication and delivery procedures. There is still considerable...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Gene-expression profiling of titanium-cell interaction

Kim CS, Hwang JW, Ryu JJ, Shin SW, Sohn SH, Kim KN, Kim MK

  • KMID: 2000734
  • J Korean Acad Prosthodont.
  • 2005 Jun;43(3):393-408.
STATEMENT OF PROBLEM: In the process of bone formation, titanium (Ti) surface roughness is an important factor modulating osteoblastic function. PURPOSE: This study was carried out to determine the effect...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Comparison of shade changes according to dry/wet condition of teeth using intra-oral colorimeter

Lee DH, Han JS, Yang JH, Lee JB

  • KMID: 2000727
  • J Korean Acad Prosthodont.
  • 2005 Jun;43(3):314-321.
OBJECTIVES: The purpose of this study was to compare the shade changes in wet and dry conditions of natural teeth using two different intra-oral colorimeters. MATERIALS AND METHODS: Twenty volunteer...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
The effect of internal implant-abutment connection and diameter on screw loosening

Ha CY, Kim CW, Lim YJ, Jang KS

  • KMID: 2000733
  • J Korean Acad Prosthodont.
  • 2005 Jun;43(3):379-392.
STATEMENT OF PROBLEM: One of the common problems of dental implant prosthesis is the loosening of the screw that connects each component, and this problem is more common in single...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Fit of fixture/abutment/screw interfaces of internal connection implant system

Kim JS, Kim HJ, Chung CH, Baek DH

  • KMID: 2000730
  • J Korean Acad Prosthodont.
  • 2005 Jun;43(3):338-351.
STATEMENT OF PROBLEM: Accurate fit between the implant components is important because the misfit of the implant components results in frequent screw loosening, irreversible screw fracture, plaque accumulation, poor soft...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
In vitro marginal fit of the computer-aided milled cercon crowns

Chang JY, Yang JH, Han JS, Lee JB

  • KMID: 2000726
  • J Korean Acad Prosthodont.
  • 2005 Jun;43(3):306-313.
STATEMENT OF PROBLEM: There have been many studies about marginal discrepancy of single restorations made by various systems and materials. But most of statistical inferences are not definite because of...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Strain on the labial plates around abutments supporting removable partial dentures with various prosthetic designs: an in vitro study

Kim SK

  • KMID: 2000728
  • J Korean Acad Prosthodont.
  • 2005 Jun;43(3):322-330.
STATEMENT OF PROBLEM: In distal extension removable partial denture, the preservation of health of abutment teeth is very important, but abutment teeth are subjected to unfavorable stress. PURPOSE: The purpose...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Comparative accuracy of the splinted and unsplinted impression methods for internal connection

Choi JH, Kim CW, Jang KS, Lim YJ

  • KMID: 2000731
  • J Korean Acad Prosthodont.
  • 2005 Jun;43(3):352-362.
STATEMENT OF PROBLEM: Accurate impression is essential to success of implant prostheses. But there have been few studies about the accuracy of fixture-level impression techniques in internal connection implant systems....
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Surface characteristics and biological responses of hydroxyapatite coating on titanium by hydrothermal method: an in vitro study

Kim DS, Kim CW, Jang KS, Lim YJ

  • KMID: 2000732
  • J Korean Acad Prosthodont.
  • 2005 Jun;43(3):363-378.
STATEMENT OF PROBLEM: Hydroxyapatite(HA) coated titanium surfaces have not yet showed the reliable osseointegration in various conditions. PURPOSE: This study was aimed to investigate microstructures, chemical composition, and surface roughness...