Skip Navigation
Skip to contents
Filter

ARTICLE TYPE

PUBLICATION DATE

11 results
Display

The physical properties of reused IPS empress ceramic part IV: Hardness and fracture toughness

Jin TH

  • KMID: 900155
  • J Korean Acad Prosthodont.
  • 2003 Aug;41(4):532-537.
STATEMENT OF THE PROBLEM: IPS Empress ceramic has been used as one of a esthetic restorative material since it's development, but the broad application of IPS Empress ceramic to clinical...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Effect of hema and tegdma on the properties of experimental composite resins

Han MH

  • KMID: 900151
  • J Korean Acad Prosthodont.
  • 2003 Aug;41(4):476-492.
PURPOSE: The purpose of this study was to compare HEMA and TEGDMA as diluents for the composite resin. MATERIAL AND METHODS: Eight kinds of experimental light curable composite resins were...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Mechanical properties of laser welded Co-Cr alloy

Bae KC, Woo YH, Lee SB

  • KMID: 900148
  • J Korean Acad Prosthodont.
  • 2003 Aug;41(4):440-450.
STATEMENT OF PROBLEM: The joints of removable partial denture alloys have failed frequently after routine usage. PURPOSE: The purpose of this study was to evaluate the mechanical properties of the...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
A study of screw loosening after dynamic continous fatigue test of several abutment screw

Kim JM, Han JS, Lee SH, Yang JH, Lee JB, Kim YS

  • KMID: 900154
  • J Korean Acad Prosthodont.
  • 2003 Aug;41(4):519-531.
STATEMENT OF PROBLEM: Chronic implant screw loosening remains a problem in restorative practices. Some implant manufactureres have introduced abutment screws with treated material, surfaces and macrostructures in an effort to...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Influence of implant-abutment interface design, implant diameter and prosthetic table width on strength of implant-abutment interface: three-dimensional finite element analysis

Oh SW, Yang JH, Lee SH, Han JS

  • KMID: 900145
  • J Korean Acad Prosthodont.
  • 2003 Aug;41(4):393-404.
STATEMENT OF PROBLEM: Higher incidence of prosthetic complications such as screw loosening, screw fracture has been reported for posterior single tooth implant. So, there is ongoing research regarding stability of...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Effects of various cements and thermocycling on retentive strengths of cemented implant-supported prostheses

Cho JH, Jeong CM, Jeon YC

  • KMID: 900150
  • J Korean Acad Prosthodont.
  • 2003 Aug;41(4):466-475.
STATEMENT OF PROBLEM: In cemented implant-supported porstheses, it is still controversy what kind of cement to use. However, the effect of thermocycling on retentive strength of cemented implantsupported prostheses has...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
The fracture resistance and stress distribution of all ceramic crowns with two types of finish line on maxillary central incisor

Ki TS, Kim KS, Lee JH, Kim YL, Dong JK

  • KMID: 900146
  • J Korean Acad Prosthodont.
  • 2003 Aug;41(4):405-420.
PURPOSE: The purpose of this sudy was to compare the fracture resistance of the IPS Empress ceramic crown with 1.0mm width rounded shoulder, which is usually recommended in all ceramic...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Computer-aided casting design for implant titanium superstructures

Oh SW, Lee HY, Lee KW, Shim JS

  • KMID: 900147
  • J Korean Acad Prosthodont.
  • 2003 Aug;41(4):421-439.
STATEMENT OF PROBLEM: It is difficult to obtain a good titanium casting body using the traditional sprue design because of high melting point of Ti, and the low fluidity and...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
A study on the fit of the implant-abutment-screw interface

Kim NH, Chung CH, Son MK, Back DH

  • KMID: 900153
  • J Korean Acad Prosthodont.
  • 2003 Aug;41(4):503-518.
STATEMENT OF PROBLEM: There have been previous studies about considerable variations in machining accuracy and consistency in the implant-abutment-screw interfaces. PURPOSE: The purpose of this study was to evaluate the...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
The effects of fabrication of gold cylinder and abutment on the fitness and preload of the prosthesis

Ha JI, Jeong HY, Kim YL, Cho HW

  • KMID: 900149
  • J Korean Acad Prosthodont.
  • 2003 Aug;41(4):451-465.
STATEMENT OF PROBLEM: Recently various implant components such as premachined gold cylinder, plastic cylinder, gold UCLA abutment and plastic abutment were developed and used clinically without clinical investigation. PURPOSE: The...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
The effect of denture cleansers on the bond strength and the surface hardness of reline resin to denture base resin

Kim KS, Jeong HY, Kim YL, Cho HW

  • KMID: 900152
  • J Korean Acad Prosthodont.
  • 2003 Aug;41(4):493-502.
STATEMENT OF PROBLEM: Removable partial denture and complete denture often require denture base relines to improve the fittness against tissue-bearing mucosa because of the gradual change in edentulous ridge contour...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close

Go to Top

Copyright © 2024 by Korean Association of Medical Journal Editors. All rights reserved.     E-mail: koreamed@kamje.or.kr