Skip Navigation
Skip to contents
Filter

ARTICLE TYPE

PUBLICATION DATE

12 results
Display

Does the maxillary anterior ratio in Korean adults follow the Golden Proportion?

Jin MX, Hong MH, Lee KJ, Lee KB

PURPOSE: The purpose of this study was to determine the effect of changes in the horizontal plane angle on the mesiodistal width ratios of the maxillary anterior teeth during the...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Fracture resistance of endodontically treated canines restored with different sizes of fiber post and all-ceramic crowns

Turker SB, Alkumru HN, Akalin B

PURPOSE: The aim of this study was to determine the fracture resistance and the mode of fracture of endodontically treated teeth restored with different fiber posts and all-ceramic crowns. MATERIALS AND...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Effects of crown retrieval on implants and the surrounding bone: a finite element analysis

Ozkir SE, Unal SM, Yurekli E, Güven S

PURPOSE: The aim of this study was to observe stress concentration in the implant, the surrounding bone, and other components under the pull-out force during the crown removal. MATERIALS AND METHODS:...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
The effect of silane applied to glass ceramics on surface structure and bonding strength at different temperatures

Yavuz T, Eraslan O

PURPOSE: To evaluate the effect of various surface treatments on the surface structure and shear bond strength (SBS) of different ceramics. MATERIALS AND METHODS: 288 specimens (lithium-disilicate, leucite-reinforced, and glass infiltrated...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Effects of hydrogen peroxide pretreatment and heat activation of silane on the shear bond strength of fiber-reinforced composite posts to resin cement

Pyun JH, Shin TB, Lee JH, Ahn KM, Kim TH, Cha HS

PURPOSE: To evaluate the effects of hydrogen peroxide pretreatment and heat activation of silane on the shear bond strength of fiber-reinforced composite posts to resin cement. MATERIALS AND METHODS: The specimens...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Finite element analysis on stress distribution of maxillary implant-retained overdentures depending on the Bar attachment design and palatal coverage

Kim MJ, Hong SO

PURPOSE: The purpose of this study was to determine the effect of anchorage systems and palatal coverage of denture base on load transfer in maxillary implant-retained overdenture. MATERIALS AND METHODS: Maxillary...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Comparison of removal torques of SLActive® implant and blasted, laser-treated titanium implant in rabbit tibia bone healed with concentrated growth factor application

Park SH, Park KS, Cho SA

PURPOSE: The purpose of this study was to compare the removal torques of a chemically modified SLActive implant and a blasted, laser-treated (BLT) implant, which were soaked in saline for...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Strains around distally inclined implants retaining mandibular overdentures with Locator attachments: an in vitro study

Elsyad MA, Setta FA, Khirallah

PURPOSE: The aim of the present study was to evaluate, by means of strain gauge analysis, the effect of different implant angulations on strains around two implants retaining mandibular overdenture...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
The selection criteria of temporary or permanent luting agents in implant-supported prostheses: in vitro study

Alvarez-Arenal A, Gonzalez-Gonzalez I, deLlanos-Lanchares H, Brizuela-Velasco A, Ellacuria-Echebarria J

PURPOSE: The use of temporary or permanent cements in fixed implant-supported prostheses is under discussion. The objective was to compare the retentiveness of one temporary and two permanent cements after...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
3D micro-CT analysis of void formations and push-out bonding strength of resin cements used for fiber post cementation

Uzun ÄH, Malkoç MA, KeleÅŸ A, Öğreten

PURPOSE: To investigate the void parameters within the resin cements used for fiber post cementation by micro-CT (µCT) and regional push-out bonding strength. MATERIALS AND METHODS: Twenty-one, single and round shaped...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Effect of different grinding burs on the physical properties of zirconia

Lee KR, Choe HC, Heo YR, Lee JJ, Son MK

PURPOSE: Grinding with less stress on 3Y-TZP through proper selection of methods and instruments can lead to a long-term success of prosthesis. The purpose of this study was to compare...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Mechanical and biological complication rates of the modified lateral-screw-retained implant prosthesis in the posterior region: an alternative to the conventional Implant prosthetic system

Lee JH, Lee JB, Kim MY, Yoon JH, Choi SH, Kim YT

PURPOSE: The modified lateral-screw-retained implant prosthesis (LSP) is designed to combine the advantages of screw- and cement-retained implant prostheses. This retrospective study evaluated the mechanical and biological complication rates of...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close

Go to Top

Copyright © 2024 by Korean Association of Medical Journal Editors. All rights reserved.     E-mail: koreamed@kamje.or.kr