Skip Navigation
Skip to contents
Filter

ARTICLE TYPE

PUBLICATION DATE

20 results
Display

Minimally invasive treatment for esthetic enhancement of white spot lesion in adjacent tooth

Lee JH, Kim DG, Park CJ, Cho LR

This article describes the treatment provided to a patient with the maxillary anterior teeth exhibiting severe secondary caries beneath the previous restoration and a white spot lesion on the adjacent...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Computerized analysis of occlusal contacts in bruxism patients treated with occlusal splint therapy

Gumus HO, Kilinc HI, Tuna SH, Ozcan N

PURPOSE: Occlusal splints are commonly used to prevent tooth wear caused by bruxism. However, the effects of splints on occlusion are still unclear. Although it is rarely alluded in literature,...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Three-dimensional finite element analysis of implant-supported crown in fibula bone model

Park YS, Kwon HB

PURPOSE: The purpose of this study was to compare stress distributions of implant-supported crown placed in fibula bone model with those in intact mandible model using three-dimensional finite element analysis. MATERIALS...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
The evaluation of maximum bite force in the occlusal rehabilitation of patient with Angle Class III malocclusion: a case report

Karakis D, Kaymak D, Dogan A

The case report describes the occlusal rehabilitation of a male patient with Angle Class III malocclusion and its effect on maximum bite force. The main complaints of patient were masticatory...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Effect of denture cleansers on surface hardness of resilient denture liners at various time intervals- an in vitro study

Pahuja RK, Garg S, Bansal S, Dang RH

PURPOSE: This study was aimed to determine the effect of two chemically distinct denture cleansers and water on the surface hardness of acrylic and silicone based soft denture liners at...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Effect of the shades of background substructures on the overall color of zirconia-based all-ceramic crowns

Suputtamongkol K, Tulapornchai C, Mamani J, Kamchatphai W, Thongpun N

PURPOSE: The objective of this study was to determine the effect of the color of a background substructure on the overall color of a zirconia-based all-ceramic crown. MATERIALS AND METHODS: Twenty...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Peel strength of denture liner to PMMA and polyamide: laser versus air-abrasion

Korkmaz FM, Bagis B, Ozcan M, Durkan R, Turgut S, Ates SM

PURPOSE: This study investigated the effect of laser parameters and air-abrasion on the peel strength of silicon-based soft denture liner to different denture resins. MATERIALS AND METHODS: Specimens (N=180) were prepared...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Assessment of demographic and clinical data related to dental implants in a group of Turkish patients treated at a university clinic

Bural C, Bilhan H, Cilingir A, Geckili O

PURPOSE: This retrospective study analyzed the distribution of the dental implants with regards to age and gender of the patients and type of indication for the implant therapy, as well...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Adhesion of 10-MDP containing resin cements to dentin with and without the etch-and-rinse technique

Turp V, Sen D, Tuncelli B, Ozcan M

PURPOSE: This study evaluated the adhesion of 10-MDP containing self-etch and self-adhesive resin cements to dentin with and without the use of etch-and-rinse technique. MATERIALS AND METHODS: Human third molars (N=180)...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Comparative study on stress distribution around internal tapered connection implants according to fit of cement- and screw-retained prostheses

Lee MY, Heo SJ, Park EJ, Park JM

PURPOSE: The aim of this study was to compare the passivity of implant superstructures by assessing the strain development around the internal tapered connection implants with strain gauges. MATERIALS AND METHODS:...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Effect of polishing and glazing on the color and spectral distribution of monolithic zirconia

Kim HK, Kim SH, Lee JB, Han JS, Yeo IS

PURPOSE: The aim of this study was to evaluate the effect of polishing and glazing on the color and spectral distribution of monolithic zirconia. MATERIALS AND METHODS: Forty-five monolithic zirconia specimens...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
A comparison of retentive strength of implant cement depending on various methods of removing provisional cement from implant abutment

Keum EC, Shin SY

PURPOSE: This study evaluated the effectiveness of various methods for removing provisional cement from implant abutments, and what effect these methods have on the retention of prosthesis during the definitive...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Stress-strain distribution at bone-implant interface of two splinted overdenture systems using 3D finite element analysis

Hussein MO

PURPOSE: This study was accomplished to assess the biomechanical state of different retaining methods of bar implant-overdenture. MATERIALS AND METHODS: Two 3D finite element models were designed. The first model included...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Effect of various intraoral repair systems on the shear bond strength of composite resin to zirconia

Han IH, Kang DW, Chung CH, Choe HC, Son MK

PURPOSE: This study compared the effect of three intraoral repair systems on the bond strength between composite resin and zirconia core. MATERIALS AND METHODS: Thirty zirconia specimens were divided into three...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Influence of various metal oxides on mechanical and physical properties of heat-cured polymethyl methacrylate denture base resins

Asar NV, Albayrak H, Korkmaz T, Turkyilmaz I

PURPOSE: To evaluate the effect of various metal oxides on impact strength (IS), fracture toughness (FT), water sorption (WSP) and solubility (WSL) of heat-cured acrylic resin. MATERIALS AND METHODS: Fifty acrylic...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Marginal fit of anterior 3-unit fixed partial zirconia restorations using different CAD/CAM systems

Song TJ, Kwon TK, Yang JH, Han JS, Lee JB, Kim SH, Yeo IS

PURPOSE: Few studies have investigated the marginal accuracy of 3-unit zirconia fixed partial dentures (FPDs) fabricated by computer-aided design/computer-aided manufacturing (CAD/CAM) system. The purpose of this study was to compare...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Perceived color shift of ceramics according to the change of illuminating light with spectroradiometer

Cha HS, Yu B, Lee YK

PURPOSE: Perceived color of ceramics changes by the spectral power distribution of ambient light. This study aimed to quantify the amount of shifts in color and color coordinates of clinically...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Focal adhesion linker proteins expression of fibroblast related to adhesion in response to different transmucosal abutment surfaces

Moon YH, Yoon MK, Moon JS, Kang JH, Kim SH, Yang HS, Kim MS

PURPOSE: To evaluate adherence of human gingival fibroblasts (HGFs) to transmucosal abutment of dental implant with different surface conditions with time and to investigate the roles of focal adhesion linker...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
The effect of different adhesive system applications on push-out bond strengths of glass fiber posts

Helvacioglu Kivanc B, Deniz Arisu H, Uctasli MB, Okay TC

PURPOSE: Over the past years, the adhesion of fiber posts luted with simplified adhesive systems has been a matter of great interest. The aim of this study was to assess...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Push-out bond strengths of fiber-reinforced composite posts with various resin cements according to the root level

Chang HS, Noh YS, Lee Y, Min KS, Bae JM

PURPOSE: The aim of this study was to determine whether the push-out bond strengths between the radicular dentin and fiber reinforced-composite (FRC) posts with various resin cements decreased or not,...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close

Go to Top

Copyright © 2024 by Korean Association of Medical Journal Editors. All rights reserved.     E-mail: koreamed@kamje.or.kr