Skip Navigation
Skip to contents
Results by Year

View Wide

Filter

ARTICLE TYPE

PUBLICATION DATE

21 results
Display

Wear of 3D printed and CAD/CAM milled interim resin materials after chewing simulation

Myagmar G, Lee JH, Ahn JS, Luke Yeo IS, Yoon HI, Han JS

PURPOSE The purpose of this in vitro study was to investigate the wear resistance and surface roughness of three interim resin materials, which were subjected to chewing simulation. MATERIALS AND...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Comparative study for osseointegration according to surface treatments of dental implants

Jun MH, Kim MJ, Sim YS, Kook MS

The purpose of this study was to evaluate the effect of hydroxyapatite (HA) full-coating and resorbable blast media (RBM) on the osseointegration of implants placed in the bone. Twelve rabbits...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Bioactive characteristics of an implant surface coated with a pH buffering agent: an in vitro study

Pae HC, Kim SK, Park JY, Song YW, Cha JK, Paik JW, Choi SH

PURPOSE: The purpose of this study was to evaluate the effectiveness of conventional sandblasted, large-grit, acid-etched (SLA) surface coated with a pH buffering solution based on surface wettability, blood protein...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Surface alterations following instrumentation with a nylon or metal brush evaluated with confocal microscopy

Kim YS, Park JB, Ko Y

PURPOSE: Surface alterations of titanium discs following instrumentation with either a nylon brush or a metal brush were evaluated. METHODS: A total of 27 titanium discs with 3 surface types (9...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Effect of Fluoride Recharging on Fluoride Release and Surface Properties of Orthodontic Bracket Adhesives

Byeon SM

The aim of this study was to compare fluoride release and surface changes according to different orthodontic bracket adhesives the application of fluoride products. We used non-fluoridated composite resin Transbond...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Surface deterioration of monolithic CAD/CAM restorative materials after artificial abrasive toothbrushing

Şen N, Tuncelli B, Göller G

PURPOSE: The purpose of this in vitro study was to evaluate the effect of abrasive toothbrushing on the surface properties of monolithic computer-assisted design and computer-assisted manufacturing (CAD/CAM) materials stored...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Influence of Implant Surface Coated with pH Buffering Agent on Early Osseointegration

Kang JH, Kim SK, Pae HC, Park JY, Cha JK, Choi SH

PURPOSE: Surface treatment with pH buffering agent has been developed to achieve higher and faster osseointegration. The aim of this study was to evaluate its influence by measuring removal torque...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Tissue integration of zirconia and titanium implants with and without buccal dehiscence defects

Lim HC, Jung RE, Hämmerle , Kim MJ, Paeng KW, Jung UW, Thoma DS

PURPOSE: The purpose of the present study was to validate an experimental model for assessing tissue integration of titanium and zirconia implants with and without buccal dehiscence defects. METHODS: In 3...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
In vitro study of Streptococcus mutans adhesion on composite resin coated with three surface sealants

Kim DH, Kwon TY

OBJECTIVES: Although the coating of surface sealants to dental composite resin may potentially reduce bacterial adhesion, there seems to be little information regarding this issue. This preliminary in vitro study...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Randomized controlled clinical trial of 2 types of hydroxyapatite-coated implants on moderate periodontitis patients

Kim HS, Yun PY, Kim YK

PURPOSE: The aim of this study was to compare and analyze the peri-implant tissue conditions and prospective clinical outcomes associated with 2 types of hydroxyapatite (HA)-coated implants: (1) fully HA-coated...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Shear bond strength of indirect composite material to monolithic zirconia

Sari F, Secilmis A, Simsek I, Ozsevik S

PURPOSE: This study aimed to evaluate the effect of surface treatments on bond strength of indirect composite material (Tescera Indirect Composite System) to monolithic zirconia (inCoris TZI). MATERIALS AND METHODS: Partially...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
The Effects of a Er:YAG Laser on Machined, Sand-Blasted and Acid-Etched, and Resorbable Blast Media Titanium Surfaces Using Confocal Microscopy and Scanning Electron Microscopy

Park JB, Kim DY, Ko Y

PURPOSE: Laser treatment has become a popular method in implant dentistry, and lasers have been used for the decontamination of implant surfaces when treating peri-implantitis. This study was performed to...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Osteoblastic behavior to zirconium coating on Ti-6Al-4V alloy

Lee BA, Kim HJ, Xuan YZ, Park YJ, Chung HJ, Kim YJ

PURPOSE: The purpose of this study was to assess the surface characteristics and the biocompatibility of zirconium (Zr) coating on Ti-6Al-4V alloy surface by radio frequency (RF) magnetron sputtering method. MATERIALS...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Early bone healing onto implant surface treated by fibronectin/oxysterol for cell adhesion/osteogenic differentiation: in vivo experimental study in dogs

Lee JS, Yang JH, Hong JY, Jung UW, Yang HC, Lee IS, Choi SH

PURPOSE: This study aimed to evaluate the effects of fibronectin and oxysterol immobilized on machined-surface dental implants for the enhancement of cell attachment and osteogenic differentiation, on peri-implant bone healing...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
The effect of pretreating resorbable blast media titanium discs with an ultrasonic scaler or toothbrush on the bacterial removal efficiency of brushing

Koh M, Park JB, Jang YJ, Ko Y

  • KMID: 2329650
  • J Periodontal Implant Sci.
  • 2013 Dec;43(6):301-307.
PURPOSE: This in vitro study was performed to assess the adherence of Porphyromonas gingivalis to a resorbable blast media (RBM) titanium surface pretreated with an ultrasonic scaler or toothbrush and...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Effect of magnesium and calcium phosphate coatings on osteoblastic responses to the titanium surface

Park KD, Lee BA, Piao XH, Lee KK, Park SW, Oh HK, Kim YJ, Park HJ

PURPOSE: The aim of this study was to evaluate the surface properties and in vitro bioactivity to osteoblasts of magnesium and magnesium-hydroxyapatite coated titanium. MATERIALS AND METHODS: Themagnesium (Mg) and magnesium-hydroxyapatite...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Effect of polishing and glazing on the color and spectral distribution of monolithic zirconia

Kim HK, Kim SH, Lee JB, Han JS, Yeo IS

PURPOSE: The aim of this study was to evaluate the effect of polishing and glazing on the color and spectral distribution of monolithic zirconia. MATERIALS AND METHODS: Forty-five monolithic zirconia specimens...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Surface characteristics and osteoblastic cell response of alkali-and heat-treated titanium-8tantalum-3niobium alloy

Lee BA, Kang CH, Vang MS, Jung YS, Piao XH, Kim OS, Chung HJ, Kim YJ

  • KMID: 2438863
  • J Periodontal Implant Sci.
  • 2012 Dec;42(6):248-255.
PURPOSE: The aim of the present study was to evaluate the biological response of alkali- and heat-treated titanium-8tantalum-3niobium surfaces by cell proliferation and alkaline phosphatase (ALP) activity analysis. METHODS: Commercial pure...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Influence of surface modification techniques on shear bond strength between different zirconia cores and veneering ceramics

Mosharraf , Rismanchian M, Savabi O, Ashtiani A

PURPOSE: Veneering porcelain might be delaminated from underlying zirconia-based ceramics. The aim of this study was the evaluation of the effect of different surface treatments and type of zirconia (white...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
The Effect of Heat Treatment and Mechanical Polishing on Nitinol Stent

Park S, Kang SG, Lee SC, Kim KS, Choi SH, Park CS, Yoon CJ, Park JH

PURPOSE: To understand the effect of heat treatment and mechanical polishing of a Nitinol wire on the chemical composition and physical morphology of the wire surface. MATERIALS AND METHODS: Stents with...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close

Go to Top

Copyright © 2022 by Korean Association of Medical Journal Editors. All rights reserved.     E-mail: koreamed@kamje.or.kr