Review of Shielding Evaluation Methodology for Facilities Using kV Energy Radiation Generating Devices Based on the NCRP-49 Report

Kwon NH, Park HS, Kim T, Kim SR, Kim KB, Kim JS, Choi SH, Kim DW

In this study, we have investigated the shielding evaluation methodology for facilities using kV energy generators. We have collected and analysis of safety evaluation criteria and methodology for overseas facilities...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Corrigendum: Assessing Commercial CLEANBOLUS Based on Silicone for Clinical Use

Son J, Jung S, Park JM, Choi CH, Kim Ji

CITED
export Copy
Close
SHARE
Twitter Facebook
Close
50–300 kVp X-ray Transmission Ratios for Lead, Steel and Concrete

Kim TH, Kim KB, Kim GB, Kim DW, Kim SR, Choi SH

The number of facilities using radiation generators increases and related regulations are strengthened, the establishment of a shielding management and evaluation technology has become important. The characteristics of the radiation...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Contribution of Microbleeds on Microvascular Magnetic Resonance Imaging Signal

Yoo CH, Goh J, Jahng GH

Purpose: Cerebral microbleeds are more susceptible than surrounding tissues and have been associated with a variety of neurological and neurodegenerative disorders that are indicative of an underlying vascular pathology. We...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Feasibility Test of Flat-Type Faraday Cup for UltrahighDose-Rate Transmission Proton Beam Therapy

Pak Si, Cho S, An S, Jeong S, Shin D, Lim Y, Jeong JH, Kim H, Lee SB

Purpose: Proton therapy has been used for optimal cancer treatment by adapting its Bragg-peak characteristics. Recently, a tissue-sparing effect was introduced in ultrahigh-dose-rate (FLASH) radiation; the high-energy transmission proton beam...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Measurement of Proton Beam Dose-Averaged Linear Energy Transfer Using a Radiochromic Film

An S, Pak Si, Jeong S, Min S, Kim TJ, Shin D, Lim Y, Jeong JH, Kim H, Lee SB

Purpose: Proton therapy has different relative biological effectiveness (RBE) compared with X-ray treatment, which is the standard in radiation therapy, and the fixed RBE value of 1.1 is widely used....
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Dead Layer Thickness and Geometry Optimization of HPGe Detector Based on Monte Carlo Simulation

Yu S, Kwon NH, Jang YJ, Lee B, Yu J, Kim DW, Cho GS, Kim KB, Kim GB, Baek CH, Choi SH

Purpose: A full-energy-peak (FEP) efficiency correction is required through a Monte Carlo simulation for accurate radioactivity measurement, considering the geometrical characteristics of the detector and the sample. However, a relative...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Effect of Bead Device Diameter on Z-Resolution Measurement in Tomosynthesis Images: A Simulation Study

Fukui R, Numata M, Nishioka S, Matsuura R, Kida K, Goto S

Purpose: To clarify the relationship between the diameter of the simulated bead and the Z-resolution of the tomosynthesis image. Methods: A simulated bead was placed on a 1,024×1,024×1,024-pixel base image. The...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Proficiency Test for the Dosimetry Audit Service Provider

Yi CY, Kim IJ, Park JI, Kim YH, Seong YM

Purpose: The proficiency test was conducted to assess the performance of the dosimetry audit service provider in the readout practice of the dose delivered to patients in medical institutions. Methods: A...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Image Guided Radiation Therapy

Hwang UJ, Min BJ, Kim M, Kim KH

Over the past decades, radiation therapy combined with imaging modalities that ensure optimal image guidance has revolutionized cancer treatment. The two major purposes of using imaging modalities in radiotherapy are...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Determination of Absorbed Dose for Gafchromic EBT3 Film Using Texture Analysis of Scanning Electron Microscopy Images: A Feasibility Study

Park SY

Purpose: We subjected scanning electron microscopic (SEM) images of the active layer of EBT3 film to texture analysis to determine the dose-response curve. Methods: Uncoated Gafchromic EBT3 films were prepared for...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Monte Carlo Investigation of Dose Enhancement due to Gold Nanoparticle in Carbon-12, Helium-4, and Proton Beam Therapy

Ahn SH

Purpose: Particle beam therapy is advantageous over photon therapy. However, adequately delivering therapeutic doses to tumors near critical organs is difficult. Nanoparticle-aided radiation therapy can be used to alleviate this...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
TET2DICOM-GUI: Graphical User Interface Based TET2DICOM Program to Convert Tetrahedral-MeshPhantom to DICOM-RT Dataset

Lee SH, Cheon BW, Min CH, Han H, Kim CH, Han MC, Kim S

Recently, tetrahedral phantoms have been newly adopted as international standard mesh-type reference computational phantoms (MRCPs) by the International Commission on Radiological Protection, and a program has been developed to convert...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Development of a Breath Control Training System for Breath-Hold Techniques and Respiratory-Gated Radiation Therapy

Choun HJ, Kim Ji, Park JM, Son J

Purpose: This study aimed to develop a breath control training system for breath-hold technique and respiratory-gated radiation therapy wherein the patients can learn breath-hold techniques in their convenient environment. Methods: The...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Minimization of Treatment Time Using Partial-Arc Volumetric Modulated Arc Therapy with Bladder Filling Protocol for Prostate Cancer

Lee H, Kim DW, Joo JH, Ki Y, Kim W, Park D, Nam J, Kim DH, Jeon H

Purpose: Radiotherapy after bladder filling protocol (BFP) is known to enhance treatment quality and reduce side effects in prostate cancer, a common male solid cancer globally. However, due to the...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Evaluation of Treatment Plan Quality between Magnetic Resonance-Guided Radiotherapy and Volumetric Modulated Arc Therapy for Prostate Cancer

Choi CH, Kim JH, Son J, Park JM, Kim Ji

Purpose: This study evaluated the quality of plans based on magnetic resonance-guided radiotherapy (MRgRT) tri-Co-60, linac, and conventional linac-based volumetric modulated arc therapy (linac-VMAT) for prostate cancer. Methods: Twenty patients suffering...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Dosimetric Evaluation of Synthetic Computed Tomography Technique on Position Variation of Air Cavity in Magnetic Resonance-Guided Radiotherapy

Jin H, An HJ, Chie EK, Park JM, Kim Ji

Purpose: This study seeks to compare the dosimetric parameters of the bulk electron density (ED) approach and synthetic computed tomography (CT) image in terms of position variation of the air...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Monte Carlo Algorithm-Based Dosimetric Comparison between Commissioning Beam Data across Two Elekta Linear Accelerators with Agility TM MLC System

Yu GB, Choi CH, Kim Ji, Cho JD, Yoon E, Choun HJ, Choi J, Kim S, Kim Y, Oh DH, Lee H, Yoo L, Chun M

Purpose: Elekta synergy ® was commissioned in the Seoul National University Veterinary Medical Teaching Hospital. Recently, Chung-Ang University Gwang Myeong Hospital commissioned Elekta Versa HD TM . The beam characteristics...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close