Risk Factors for Pulmonary Cement Embolism (PCE) After Polymethylmethacrylate Augmentation: Analysis of 32 PCE Cases

Guo H, Huang H, Shao Y, Qin Q, Liang D, Zhang S, Tang Y

Objective: Pulmonary cement embolism (PCE) is an underestimated but potentially fatal complication after cement augmentation. Although the treatment and follow-up of PCE have been reported in the literature, the risk...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Color stability of 3D-printed denture resins: effect of aging, mechanical brushing and immersion in staining medium

Alfouzan AF, Alotiabi HM, Labban N, Al-Otaibi HN, Al Taweel SM, AlShehri HA

Purpose This in-vitro study evaluated and compared the color stability of 3D-printed and conventional heat-polymerized acrylic resins following aging, mechanical brushing, and immersion in staining medium. Materials and methods Forty...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Polishing characteristics of polyetherketoneketone on Candida albicans adhesion

Kim H, Lee J, Lee SH, Baek D

Purpose: To compare the polishing characteristics and their influence on Candida albicans adhesion to the recently introduced polyetherketoneketone (PEKK) and the conventional polymethylmethacrylate (PMMA) denture resin material. Materials and methods:...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Comparative study of surface modification on bond strength of polyetherketoneketone adhesively bonded to resins for temporary restoration

Hong MG, Shin SY

Purpose: The purpose was to compare shear bond strength (SBS) of three types of resin for temporary restoration to polyetherketoneketone (PEKK) depending on surface modification. Materials and Methods: Sixty disks...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Color alterations of a PMMA resin for fixed interim prostheses reinforced with silica nanoparticles

Kotanidis , Kontonasaki E, Koidis P

PURPOSE: The aim of the present study was to evaluate the color changes of an autopolymerizing PMMA resin used for interim fixed restorations, reinforced with SiO2 nanoparticles. MATERIALS AND METHODS: Silica...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Surgical Treatment of Osteoporotic Vertebral Compression Fractures at Thoraco-Lumbar Levels: Only Pedicle Screw Constructs with Polymethylmethacrylate Augmentation

Jun DS, Baik JM, Park JH

PURPOSE: To investigate the radiological efficacy of polymethylmethacrylate (PMMA) augmentation of pedicle screw operation in osteoporotic vertebral compression fractures (OVCF) patients. MATERIALS AND METHODS: Twenty OVCF patients, who underwent only posterior...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Effect of delayed time, surface treatment, and repair material on shear bond strength of repaired bis-acryl composite resin

Park JS, Lee JI

PURPOSE: The aim of this study was to evaluate the effect of delayed time, surface treatment, and repair materials on repair of bisacryl composite resin through comparison of shear bond...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Pulmonary Embolism from Cement Augmentation of the Vertebral Body

Ignacio JM, Ignacio KH

Pulmonary cement embolism (PCE) can follow cement augmentation procedures for spine fractures due to osteoporosis, traumatic injuries, and painful metastatic lesions. PCE is underreported and it is likely that many...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Pullout Strength after Expandable Polymethylmethacrylate Transpedicular Screw Augmentation for Pedicle Screw Loosening

Kang SH, Cho YJ, Kim YB, Park SW

OBJECTIVE: Pedicle screw fixation for spine arthrodesis is a useful procedure for the treatment of spinal disorders. However, instrument failure often occurs, and pedicle screw loosening is the initial step...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Giant Cell Tumor of Upper Thoracic Spine

Lee CG, Kim SH, Kim DM, Kim SW

Giant cell tumor (GCT) of the spine is a rare benign tumor, but can be aggressive and can exhibit a high local recurrence rate. Furthermore, GCT of the upper thoracic...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Model of Induced Leakage of Polymethylmethacrilate Inside Epidural Space and Prevertebral Muscles During Vertebroplasty in Pigs: Clinical, Macroscopical, and Histological Study

Silva Gonzalez A, Alfonso Olmos M, Villas Tome C, Angulo MG

STUDY DESIGN: Experimental study in animals. PURPOSE: Study the clinical behavior of animals after an induced leakage of cement during vertebroplasty in pigs. Study the distribution of polymethylmetacrilate inside the epidural...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
CT-Guided Percutaneous Vertebroplasty in the Treatment of an Upper Thoracic Compression Fracture

Seong JY, Kim JS, Jung B, Lee SH, Kang HY

Percutaneous vertebroplasty (PVP) has been used to relieve pain and to prevent further collapse of the vertebral body in patients with an osteoporotic compression fracture. The most commonly affected site...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Numerous Bilateral Radiographically Dense Branching Opacities after Vertebroplasty with Polymethylmethacrylate

Cho JH, Jung JP, Eum JB, Seo KW, Jegal YJ, Choi SH, Ahn JJ

  • KMID: 2318913
  • Tuberc Respir Dis.
  • 2006 Aug;61(2):184-188.
Percutaneous vertebroplasty consists of the percutaneous injection of polymethylmethacrylate (PMMA) cement into a collapsed vertebral body in order to obtain pain relief and mechanically strengthen the vertebral body. This procedure...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Two Cases of Linear Scleroderma 'En Coup de Sabre' Treated with Polymethylmethacrylate Microspheres (PMMA-NewPlastic(R))

Park JH, Oh DJ, Kang SH, Hwang SW, Cho SH, Park SW

  • KMID: 1639699
  • Korean J Dermatol.
  • 2006 Apr;44(4):512-514.
Localized scleroderma is a disease of unknown origin and is characterized by circumscribed sclerotic skin changes. When occurring in a linear pattern, it is called linear scleroderma. 'En coup de...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
The Analysis of Polymethylmethacrylate Leakage after Vertebroplasty for Vertebral Body Compression Fractures

Do HW, Kwon YJ, Yang JY, Choi CS, Ju MB

  • KMID: 2018723
  • J Korean Neurosurg Soc.
  • 2004 May;35(5):478-482.
OBJECTIVE: To assess causative factors that may induce the leakage of the PMMA after the vertebroplasty performed on osteoporotic compression fracture patients. METHODS: Percutaneous vertebroplasty was done on 80 vertebral...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Vertebroplasty for the Treatment of Painful Osteoporotic Compression Fractures

Kim YW, Chang HG, Lee KB, Ji YN, Lee YB, Ku JM

PURPOSE: To evaluate results regarding pain relief, spinal stabilization, and complication after treatment with percutaneous vertebroplasty. MATERIALS AND METHODS: 108 patients (12 men, 96 women; aged 42~84 years) underwent 156...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Percutaneous Vertebroplasty in the Treatment of Senile Osteoporotic Vertebral Body Compression Fractures: Treatment Efficacy and Complications

Kang DH, Kim KJ, Lee CH, Hwang SH, Kim ES, Jung JM

  • KMID: 1817283
  • J Korean Geriatr Soc.
  • 2002 Sep;6(3):212-221.
BACKGROUNDS: The purpose of this study is to clarify therapeutic efficacy of percutaneous vertebroplasty(PVP) using polymethylmethacrylate(PMMA) for the osteoporotic compression fractures of the spine and to define the complications following...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Pulmonary Embolism after Percutaneous Vertebroplasty with Polymethylmethacrylate: Case Report

Ha SK, Lim DJ, Song WH, Park JY, Kim SH, Cho TH, Chung YG, Suh JK

  • KMID: 2018616
  • J Korean Neurosurg Soc.
  • 2002 Aug;32(2):165-168.
We present a case with rare complication of percutaneous vertebroplasty with polymethylmethacrylate (PMMA). A pulmonary embolus was detected in a 79-year-old woman with osteoporotic compression fracture after percutaneous verteroplasty. Chest...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Surgical Treatment of Spinal Plasma Cell Tumors

Shin MJ, Oh SH, Yoon DH, Chin DK, Cho YE, Kim YS

  • KMID: 2018607
  • J Korean Neurosurg Soc.
  • 2002 Aug;32(2):118-124.
OBJECTIVE: The purpose of this study is to review the cases of spinal plasma cell tumors treated in our department with regard to presenting symptoms and signs, diagnostic investigations, extent...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Barrier Techniques for Spinal Cord Protection from Thermal Injury in Polymethylmethacrylate Reconstruction of Vertebral Body:Experimental and Theoretical Analyses

Park CK, Ji C, Hwang JH, Kwun SO, Sung JH, Choi SJ, Lee SW, Park SC, Cho KS, Park CK, Yuan HS, Kang JK

  • KMID: 2018409
  • J Korean Neurosurg Soc.
  • 2001 Mar;30(3):272-277.
OBJECTIVES: Polymethylmethacrylate(PMMA) is often used to reconstruct the spine after total corpectomy, but the exothermic curing of liquid PMMA poses a risk of thermal injury to the spinal cord....
CITED
export Copy
Close
SHARE
Twitter Facebook
Close

Go to Top