Skip Navigation
Skip to contents
Results by Year

View Wide

Filter

ARTICLE TYPE

more+
SELECT FILTER
 
Close

PUBLICATION DATE

134 results
Display

Desaturation of Pulse Oximetry by Intraoperative Using of Subcutaneous Blue Dye: A case report

Shim JY, Park CM, Cho SH

Pulse oximetry is a noninvasive, reusable device that is being used routinely in anesthesia procedure for monitoring oxygen saturation. This is a very beneficial device that can quickly detect of...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Pulse Oximetry

Park JM

No abstract available.
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Pulse Oximetry

Koh SO

Pulse oximetry has rapidly become the primary means of assuring safety of anesthesia, postoperative patient transport, recovery, critical care and other patient care situations potentially involving ventilatory depression, airway obstruction,...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Survey of the Knowledge about Pulse Oximetry in Medical Personnel

Jeon BY, Ryu SJ, Kim KH, Jang TH, Kim SH

BACKGROUND: Pulse oximetry has been recommended as a standard of care for ICU, CCU, Post Anesthetic Care Unit as well as general anesthesia. The device provides valuable data regarding blood...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Pulse Oximetry during Shunt Surgery in Pediatric Patients with Tetralogy of Fallot

Oh HK, Park WK, Nam SH, Bang SO, Cho SC

Pulse oximetry is a relatively new and noninvasive technique for measuring O2 saturation continuously. We applied pulse oximetry to 9 pediatric patients with tetralogy of Fallot during shunt surgery. Arterial...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Pulmonary Artery Catheterization and Mixed Venous Oximetry

Choi JM

No abstract available.
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Pulse oximetry during shunt surgery in pediatric patients with tetralogy of fallot

Oh HK, Park WK, Nam SH, Bang SO

Pulse oximetry is a noninvasive technique for measuring O2 saturation (SpO2) continuously. We applied pulse oximetry to 9 pediatric patients with tetralogy of Fallot during shunt surgery. Arterial oxygen tensions...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Measurement of oxygen saturation of the diabetic limbs by pulse oximetry

Lee EW, Jang EC, Kim KS, Kim HK, Lee HJ

  • KMID: 1691208
  • J Korean Orthop Assoc.
  • 1993 Dec;28(7):2491-2497.
No abstract available.
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Comparative Study on Quantitation of Left to Right Shunts in Ventricular Septal Defect Using Oximetry and Radionuclide Method

Hong CY, Choi JY, Park SW, Yun YS, Koh CS

  • KMID: 1676189
  • J Korean Pediatr Soc.
  • 1985 Apr;28(4):340-344.
No abstract available.
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Anesthetic management of a patient with hemoglobinopathy: A case report

Lee HS, Lee JY, Kim JY, Lee HJ

  • KMID: 2169143
  • Anesth Pain Med.
  • 2012 Jan;7(1):30-33.
Hemoglobinopathy poses many challenges to the anesthesiologists. The central issue is the accuracy about interpretation of pulse oximetry saturation value during anesthesia. There are limited data with respect to the...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Effect of position change on oxygen saturation(SpO2)by pulse oximetry in the newborn infants

Chang YS, Won YS, Kim MJ, Son DW, Kim BI, Choi JH, Yun CK

  • KMID: 1691513
  • Korean J Perinatol.
  • 1993 Sep;4(3):295-304.
No abstract available.
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Newborn Screening for Critical Congenital Heart Defects Using Pulse Oximetry

Shin J, Choi BM

Critical congenital heart defects can lead to serious morbidity and mortality if not found at the appropriate time. Although prenatal ultrasound and postnatal neonatal physical examination can detect the majority...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Full Thickness Burn on the Finger due to Pulse Oximetry during Magnetic Resonance Imaging in a Conscious Patient

Sung SJ, Park YS, Cho JY

No abstract available.
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Digital Pulse Oximetry for the Screeing of Lower Extremity Arterial Disease

Shim DM, Oh SK, Kwon JN

STUDY DESIGN: Retrospective study. OBJECTIVES: The aim of the study was to investigate the usefulness of a handheld digital pulse oximetry in the detection of lower extremity arterial disease. SUMMARY OF LITERATURE...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Cerebral Oxygen Saturation Monitoring during Carotid Endarterectomy: A case report

Kang MS, Oh YS

Cerebral oximetry based on the principle of near infrared spectroscopy is a relatively new technique that can monitor changes in cerebral oxygenation. Limited clinical experience with this monitoring technique exists,...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
False Low Pulse Oximetry Reading following a Peritumoral Injection of 1% Isosulfan Blue Dye in a Patient with Breast Cancer

Jo HY, Lee SG, Son JS, Jung SH

Pulse oximetry is a noninvasive, continuous monitoring of arterial oxygenation and provides rapid detection of perioperative hypoxemia. However, many factors give a factitious reading of hemoglobin desaturation, some of these...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Clinical Study on Oxygen Saturation Changes During Tonsillectomy Under Local Anesthesia and Administration of Supplementary Oxygen

Kim HM, Lee MK, Park YC, Yoon SM, Lim SH, Kim NS, Choi YS

CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Cerebral Oxygen Saturation Monitoring during Aortic Dissection Surgery: A case report

Kim CG, Hwang JW, Ham BM

Transcranial cerebral oximetry has been successfully used in a variety of neurosurgical conditions, primarily those associated with disturbed cerebral circulation. It has been also used in intraoperative monitoring of aortic...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Diagnosis of Obstructive Sleep Apnea Syndrome Using Overnight Oximetry Measurement

Youn T, Park DH, Choi KH, Kim YS, Woo JI, Kwon JS, Ha KS, Jeong DU

  • KMID: 2317372
  • Sleep Med Psychophysiol.
  • 2002 Jun;9(1):34-40.
OBJECTIVES: The gold standard for diagnosing obstructive sleep apnea syndrome (OSAS) is nocturnal polysomnography (NPSG). This is rather expensive and somewhat inconvenient, however, and consequently simpler and cheaper alternatives to...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Validity on Postoperative Routine Supplemental Oxygen Using Pules Oximetry-Determining factor on the Postoperative Arterial Hypoxemia

Han JI, Lee GY, Chung RJ, Whang HJ, Lee CH

Routine use of supplemental oxygen(O2) in the recovery room traditionslly has been used to minimize the incidence of hypoxemia. However with the advent of continuous noninvasive monitoring by pulse oximetry...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close

Go to Top

Copyright © 2024 by Korean Association of Medical Journal Editors. All rights reserved.     E-mail: koreamed@kamje.or.kr