Efficacy and Safety of a Pressurized Metered-Dose Inhaler in Older Asthmatics: Comparison to a Dry Powder Inhaler in a 12-Week Randomized Trial

Woo SD, Ye YM, Lee Y, Lee SH, Shin YS, Park JH, Choi H, Lee HY, Shin HJ, Park HS

PURPOSE: Asthma control in older asthmatics is often less effective, which may be attributed to small airway dysfunction and poor inhalation technique. We compared the efficacy of 2 inhalers (fluticasone...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Continued Innovation in Respiratory Care: The Importance of Inhaler Devices

Bosnic-Anticevich SZ

When it comes to the use in inhalers in the management of chronic obstructive pulmonary diseases, there are many options, considerations and challenges, which health care professionals need to address....
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Treatment Result of Proton Pump Inhibitor, Steroid Inhaler and Botulinum Tonxin Injection for Contact Granuloma

Park HM, Oh NR, Baek MK, Kim DY, Woo JH

BACKGROUND AND OBJECTIVES: This study evaluated the efficacy of combination therapy of proton pump inhibitor (PPI) and steroid inhaler (SI), with or without botulinum toxin injection (BTX) for contact granuloma. SUBJECTS...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Short-term Evaluation of a Comprehensive Education Program Including Inhaler Training and Disease Management on Chronic Obstructive Pulmonary Disease

Yoo KH, Chung WY, Park JH, Hwang SC, Kim TE, Oh MJ, Kang DR, Rhee CK, Yoon HK, Kim TH, Kim DK, Park YB, Kim SH, Yum HK

BACKGROUND: Proper education regarding inhaler usage and optimal management of chronic obstructive pulmonary disease (COPD) is essential for effectively treating patients with COPD. This study was conducted to evaluate the...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Outcome of Inhaler Withdrawal in Patients Receiving Triple Therapy for COPD

Kim SA, Lee JH, Kim EK, Kim TH, Kim WJ, Lee JH, Yoon HI, Baek S, Lee JS, Oh YM, Lee SD

BACKGROUND: The purpose of this study was to document outcomes following withdrawal of a single inhaler (step-down) in chronic obstructive pulmonary disease (COPD) patients on triple therapy (long-acting muscarinic antagonist...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Inhaler Competency and Medication Adherence in Older Adults and Adults with Obstructive Lung Disease

Kim SJ, Shin YS

PURPOSE: The aims of current study were to assess the inhaler competency and medication adherence, and to identify association of inhaler competency with medication adherence in patients with obstructive lung...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Recent advance in inhaler medications for chronic obstructive pulmonary disease patients

Oh YM

  • KMID: 2342368
  • J Korean Med Assoc.
  • 2014 Feb;57(2):155-158.
Chronic obstructive pulmonary disease (COPD) is one of the highest ranking diseases with regard to prevalence and mortality in Korea and also worldwide. In the past decade, effective inhaler medications...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Awareness during General Anesthesia due to Vaporizer Malfunction: A case report

Seol TK, Sim J, Park HY, Ahn W

We report a case of awakening during general anesthesia due to a vaporizer malfunction. The sevoflurane vaporizer had a hole through which approximately 20% of fresh gas escaped. The gas...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
A Survey of Home Nebulizer Use and Its Contamination in Asthmatic Children

  • KMID: 2299626
  • Korean J Asthma Allergy Clin Immunol.
  • 2007 Mar;27(1):50-56.
BACKGROUND AND OBJECTIVE: Home nebulizers have been widely used among patients with asthma. The aim of this study was to evaluate whether the patients could use home nebulizers properly as...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Effect of Administration Method of Isoflurane on Bispectral Index Values in the Early Period of Cesarean Section: A Comparison of End-Tidal or Vaporizer Concentration using Overpressure

Lee HJ, Kim JB, Choi HJ

BACKGROUND: Patients undergoing a cesarean section under general anesthesia are at risk of intraoperative awareness due to the use of low concentration of volatile anesthetics used. This study...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
An Unexpected Vapor Leakage from Unlocked Vaporizer (Penlon Sigma Delta Anesthetic Vaporizer): A case report

Lee SY, Suh SH, Cho JH, Lim JA, Lee KM, Woo NS

We present a case of an anesthetic gas leak through the valve of the Selectatec back bar during a surgical procedure. The Selectatec Vaporizing System is a quick-change system consisting...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Bacterial Contaminations of Home Nebulizers in Asthmatic Children

Yoo Y, Seo KJ, Kim TY, Lee Y, Choung JT, Roh KH

  • KMID: 2314411
  • Pediatr Allergy Respir Dis.
  • 2006 Jun;16(2):122-130.
PURPOSE: Nebulizers are commonly used to treat children with asthma. Some pulmonary infections associated with contaminated nebulizer units have been reported. The aims of this study were to determine whether...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
The Effect of Antibiotic Nebulizer Therapy for Treatment of Pediatric Chronic Rhinosinusitis

Min KK, Kim SY, Kang IG, Cha HE, Kim ST

  • KMID: 1977290
  • Korean J Otolaryngol-Head Neck Surg.
  • 2006 Oct;49(10):997-1002.
BACKGROUND AND OBJECTIVES : The management of chronic recurrent rhinosinusitis in children has become controversial, because there are now various treatment modalities. We assessed nebulized antibiotic therapy, which had been...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Comparative Study of Nebulizer Output and Particle Size for Standardization of Inhalation Provocation Test

Hwang EK, Kim HJ, Kim KS, Jang W, Han MY, Moon SH

  • KMID: 2314274
  • Pediatr Allergy Respir Dis.
  • 2003 Mar;13(1):47-54.
PURPOSE: It is very important to compare the particle size and total output from inhalation devices for standardization of bronchial provocation test. METHODS: Total output (mass output, salt output) from...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Estimation of the Possible Age for Using Various Types of Inhaler by In-Check Inspiratory Flow Meter(TM)

Jung KH, Kim SY, Lee JH, Kim KS, Jang Y, Han MY

  • KMID: 2335578
  • J Korean Pediatr Soc.
  • 2002 Feb;45(2):192-198.
PURPOSE: It is important to select and use kinds of Inhaler appropriate to the age of the patient and severity of symptoms. Several kinds of Inhaler have been developed and...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
The Study of Home Nebulizer Use in Asthmatic Children

Rhee SE, Kim CH, Choi JY, Son MH, Kim KE, Lee KY

  • KMID: 2314217
  • Pediatr Allergy Respir Dis.
  • 2000 Jun;10(2):141-152.
PURPOSE: Inhalational therapy is now one of the major method in managing asthma. Nebulizer is widely used at home nowadays, but there has been no survey on the usage of...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Inhalation of Bronchodilator Aerosol by Metered-dose Inhaler and Spacer in Neonatal Respiratory Distress Syndrome

Lee HS

  • KMID: 1829637
  • J Korean Pediatr Soc.
  • 1999 Dec;42(12):1668-1675.
PURPOSE: To examine the clinical effects of two bronchodilator agents, salbutamol and ipratropium bromide, administered by metered-dose inhaler(MDIS) to preterm infants with respiratory distress syndrome(RDS) during mechanical ventilation. METHODS: This...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Research Output Accuracies of Private Hospital Vaporizers

Bae KY, Lew GS, Kim HM, Joo JC

BACKGROUND: Vaporizers convert liquid anesthetics into measured amount of vapor that are added to the fresh gas mixture to produce known concentrations of anesthetics. As with anesthesia machines, mordern precision...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Comparison of therapeutic effect of metered dose inhaler with spacer and nebulizer in acute childhood asthma

Whang IT, Hong YM, Lee SJ

  • KMID: 1693549
  • Allergy.
  • 1993 May;13(2):229-237.
No abstract available.
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Overdose with Malfunctional Halothane Vaporizer

Kim SY, Lee YW, Lee YS, Kim JS, Nam SC, Kim JR

A Vaporizer should deliver a constant concentration of anesthetics under the varying conditions of gas flow, liquid volume, and ambient temperature. We had encountered 3 patients with arrhythmia and...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close

Go to Top