Skip Navigation
Skip to contents
Filter

ARTICLE TYPE

PUBLICATION DATE

7 results
Display

Report of the Korean Association of External Quality Assessment Service on Qualitative Testing of Molecular Virology (2016–2020)

Park , K, Kim MN, Sung H

For this study, we reviewed the surveys on qualitative testing of molecular virology conducted by the Korean Association of External Quality Assessment Service from 2016 to 2020. For this proficiency...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Report of the Korean Association of External Quality Assessment Service on General and Specialized Coagulation Tests in Korea (2016–2019)

Jang S, Kim H, goong SN, Kim T

The Korean Association of External Quality Assessment Service offered to conduct a proficiency test program for general and specialized coagulation testing. In this report, we have summarized the results of...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Annual Report of the Korean Association of External Quality Assessment Service on General Chemistry (2020)

Lee YW

In 2020, the general chemistry proficiency testing program of the Korean Association of External Quality Assessment Service consisted of routine and urine chemistry programs including 29 and 13 test items,...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Clinical Utility of Reticulocyte Hemoglobin Equivalent in Diagnosing Iron Deficiency Anemia

Park KJ, Kim MJ

Background: Iron deficiency anemia (IDA) is one of the major global public health problems. Reticulocyte hemoglobin (Hb) equivalent (Ret-He) has been proposed as an early index for IDA. However, little...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Multicenter Verification of a Harmonized Test Method for Human Leukocyte Antigen Flow Cytometry Crossmatching

Park Y, Park MH, Park BG, Oh EJ, Bang HI, Lee JH, Kang ES

Background: Flow cytometry crossmatch (FCXM) is the most sensitive method currently used for human leukocyte antigen (HLA) crossmatches. The FCXM test methods and cut-off values used to determine the positive reaction...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Implementation and Validation of a Gas Chromatography-Mass Spectrometry Method for Pristanic Acid and Phytanic Acid Quantification in Plasma Specimens

Yi A, Lee JH, Yoo G, Lim HJ, Park E, Han J, Kim GY, Cho SE, Lee SG, Lee EH

We validated a gas chromatography-mass spectrometry (GC-MS) method for quantifying pristanic acid (PrA) and phytanic acid (PhA) in plasma specimens. We developed a GC-MS method based on the analysis of 20...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Impact of Whole Blood Storage Conditions in Flow Cytometric Analysis for Paroxysmal Nocturnal Hemoglobinuria

Yoon S, Kim J, Kim SY, Lim J, Kwon GC, Koo SH

Background: We evaluated the effect of four blood storage conditions (refrigeration, fixation [with the Cyto-Chex and TransFix tubes], and physiologic stabilization using Ficoll polymer PM70) for 72 hours in flow...