Skip Navigation
Skip to contents
Filter

ARTICLE TYPE

PUBLICATION DATE

8 results
Display

A Novel Four-Way Translocation t(5;9;22;18)(q31;q34;q11.2;q21) in a Patient with Chronic Myelogenous Leukemia

Kim WS, Park G, Jang SJ, Moon DS, Kang SH

Chronic myelogenous leukemia (CML) is characterized by the presence of the Philadelphia chromosome, which is generated by a reciprocal t(9;22)(q34;q11) translocation. Variant Philadelphia chromosomes, found in 5-10% of CML cases,...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Performance Evaluation of the Elecsys Neuron-Specific Enolase Assay

Kim SK, Jeong TD, Lee W, Chun S, Min WK

BACKGROUND: Neuron-specific enolase (NSE) is an enzyme specifically found in neurons and neuroendocrine tissue. It is a common marker for small cell lung cancer diagnosis and is also useful as...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Evaluation of i-STAT CHEM8+ Point-of-Care Chemistry Analyzer

Kim DK, Shin H, Kim B, Jeong SH, Lim JB

BACKGROUND: We evaluated the analytical performance of the Abbott i-STAT CHEM8+, a point-of-care testing system that measures 8 basic chemical analytes, namely, sodium, potassium, chloride, total carbon dioxide, BUN, creatinine,...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
A Comparison of the Performance of Soyagreentec Ampulab EDTA and Sodium Citrate Tubes with That of BD Vacutainer Tubes

Lee JH, Cha YJ, Lee DS, Kim SY

BACKGROUND: Because blood collection tube can affect the results of various laboratory tests, it is necessary before using a newly developed product to verify its performance stringently and objectively. We...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Vitamin D Levels and Prevalence of Vitamin D Deficiency Associated with Sex, Age, Region, and Season in Koreans

Nah EH, Kim S, Cho HI

BACKGROUND: Although many studies on vitamin D have been conducted, they have not been consistent regarding the method of measurement, the individuals investigated, and the season of blood sampling. Thus,...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Performance Evaluation of BAROZEN H, a Networking Blood Glucose Monitoring System for Medical Institutions

Lee JH, Cha YJ

BACKGROUND: We evaluated the analytical performance of Barozen H (i-SENS Inc., Korea), a new glucometer equipped with networking function for medical institutions, according to the ISO 15197:2003 and ISO/DIS 15197:2011...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Evaluation of Centaur Syphilis, Immulite Syphilis, and Mediace TPLA for Detecting Treponemal Antibodies

Seo DH, Whang DH, Joo SY, Choi HH

BACKGROUND: We evaluated the efficacy of two chemiluminescence immunoassays that detect treponemal antibodies, Centaur Syphilis and Immulite Syphilis, in comparison with Mediace Treponema pallidum latex agglutination (TPLA). METHODS: The study was...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Anti-Proliferating Cell Nuclear Antigen Antibodies Detected in Rheumatoid Arthritis: A Case Report

Song SD, Kim TY

Rheumatoid arthritis (RA) is an autoimmune disease that results in a chronic inflammatory disorder, which principally attacks the small joints. Several autoantibodies, such as rheumatoid factor (RF) and anti-cyclic citrullinated...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close

Go to Top

Copyright © 2024 by Korean Association of Medical Journal Editors. All rights reserved.     E-mail: koreamed@kamje.or.kr