Skip Navigation
Skip to contents
Filter

ARTICLE TYPE

PUBLICATION DATE

7 results
Display

Comparison of the shear bond strength of brackets in regards to the light curing source

Cha JY, Lee KJ, Park SH, Kim TW, Yu HS

  • KMID: 2273333
  • Korean J Orthod.
  • 2006 Jun;36(3):198-206.
With the introduction of the xenon plasma arc curing light and the LED curing light as orthodontic curing lights, the polymerizing time of orthodontic composites has clearly decreased. In contrast...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Frictional resistance of different ceramic brackets and their relationship to the second order angulation between bracket slot and wire

Choi YJ, Park YC

  • KMID: 2273334
  • Korean J Orthod.
  • 2006 Jun;36(3):207-217.
Although ceramic brackets have been used widely for improved esthetics during treatment, ceramic brackets have some inherent problems; brittleness, attrition of the opposing teeth and high frictional resistance. This study...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Bond strength of fiber reinforced composite after repair

Kim MJ, Kim KH, Choy K

  • KMID: 2273332
  • Korean J Orthod.
  • 2006 Jun;36(3):188-197.
Fiber reinforced composite (FRC) is usually used as a connector joining a few teeth into one unit in orthodontics. However, fracture often occurs during the two to three years of...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
A cephalometric and dental cast study of obstructive sleep apnea patients

Jung MR, Hwang SH, Nam KY, Kim JB, Kwon OW

  • KMID: 2273336
  • Korean J Orthod.
  • 2006 Jun;36(3):228-236.
To evaluate the cephalometric and dental characteristics of obstructive sleep apnea (OSA) patients, 23 OSA patients and 15 control, non-OSA, patients who visited the Sleep Disorder Clinic Center, Keimyung University...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Comparison of histologic observation and insertional and removal torque values between titanium grade 2 and 4 microimplants

Kang ST, Kwon OW, Sung JH, Kyung HM, Park HS

  • KMID: 2273330
  • Korean J Orthod.
  • 2006 Jun;36(3):171-177.
The purpose of this study was to evaluate the light microscopic features and the maximum insertional and removal torque value of microimplants, made from titanium grade 2 or 4, in...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
A study on the correlations between facial biotype, submentovertex cephalometric measurements and surface EMG activity in patients with facial asymmetry

Kim SS, Cha BK, Lee NK

  • KMID: 2273335
  • Korean J Orthod.
  • 2006 Jun;36(3):218-227.
Although the submentovertex radiograph and surface EMG are not often used due to the difficulty of interpretation, they are accepted as useful diagnostic and analytic aids for skeletal asymmetry. There...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Three-dimensional finite element analysis for stress distribution on the diameter of orthodontic mini-implants and insertion angle to the bone surface

Byoun NY, Nam EH, Yoon YA, Kim IK

  • KMID: 2273331
  • Korean J Orthod.
  • 2006 Jun;36(3):178-187.
The present study was performed to evaluate the stress distribution on the diameter of the mini-implant and insertion angle to the bone surface. To perform three dimensional finite element analysis,...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close

Go to Top

Copyright © 2024 by Korean Association of Medical Journal Editors. All rights reserved.     E-mail: koreamed@kamje.or.kr