Development of Electronic Medical Chart for Radiation Oncology

Cho SJ, Shim SJ, Lee S, Lee SH, Cho KH, Huh HD, Lim S, Choi JH, Choi JY, Yun HG, Shin DO

  • KMID: 2038091
  • Korean J Med Phys.
  • 2009 Sep;20(3):167-173.
As the radiotherapy technique development, the needs for using of medical electronic chart in the department of radiation oncology is growing. However, the complexity of affairs of radiation oncology make...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Verification of X-sight Lung Tracking System in the CyberKnife

Huh HD, Choi SH, Kim WC, Kim HJ, Kim SH, Cho SJ, Min CK, Cho KH, Lee SH, Choi J, Lim S, Shin DO

  • KMID: 2038092
  • Korean J Med Phys.
  • 2009 Sep;20(3):174-179.
To track moving tumor in real time, CyberKnife system imports a technique of the synchrony respiratory tracking system. The fiducial marker which are detectable in X-ray images were demand in...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
A Study on Fatigue Characteristic of Stent Using Finite Element Analysis

Kim HK, Shin IG, Kim DG, Kim SH, Lee JH, Ki BY, Suh TS, Kim SH

  • KMID: 2038084
  • Korean J Med Phys.
  • 2009 Sep;20(3):119-124.
Stents are frequently used throughout the human body. They keep pathways open in vascular or nonvascular duct for a long time. Therefore its stability is very important factor. In recent...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Estimation and Application of HU Values for Various Materials as Function of Physical Factor

Lee SW, Kim HJ, Kim TH, Jo SJ, Lee CL

  • KMID: 2038088
  • Korean J Med Phys.
  • 2009 Sep;20(3):145-151.
This study aims to evaluate CT (Computed Tomography) characteristics through the estimation of HU (Hounsfield Unit) and the corresponding variations using coefficient of variation values for various materials as a...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Comparison of F-18 FDG Radioacitivity to Determine Accurate Dose Calibrator Activity Measurements

Jin GH, Kweon DC, Oh KB, Park HH, Kim JY, Park MS, Park DS

  • KMID: 2038090
  • Korean J Med Phys.
  • 2009 Sep;20(3):159-166.
Obviously, the administration of the prescribed amount of activity to the patient requires proper operation of the dose calibrator, which shall be verified by implementing the required quality control on...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
The Verification of Computer Simulation of Nitinol Wire Stent Using Finite Element Analysis

Kim JY, Jung WG, Jeon DM, Shin IG, Kim HK, Shin DO, Kim SH, Suh TS

  • KMID: 2038087
  • Korean J Med Phys.
  • 2009 Sep;20(3):139-144.
Recently, the mathematical analysis of stent simulation has been improved, with the help of development of various tool which measure mechanical property and location of stent in artery. The most...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Automated Determination of Prostate Depth for Planning in Proton Beam Treatment

Cheong M, Yoon M, Kim J, Shin DH, Park SY, Lee SB

  • KMID: 2038093
  • Korean J Med Phys.
  • 2009 Sep;20(3):180-190.
Depth of prostate volume from the skin can vary due to intra-fractional and inter-fractional movements, which may result in dose reduction to the target volume. Therefore we evaluated the feasibility...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Study of Acute Myelocytic Leukemia Patient Treatment That Used Total Skin Electron Beam

Lee SR, Kang MK, Kim SK

  • KMID: 2038089
  • Korean J Med Phys.
  • 2009 Sep;20(3):152-158.
Total Skin Electron Beam Therapy (TSEBT) of linear accelerator has become use so as to be useful, 2~9 MeV of energy territories came to be used with mycosis fungoides and...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Prediction of Target Motion Using Neural Network for 4-dimensional Radiation Therapy

Lee SK, Kim YN, Park KR, Jeong K, Lee CG, Lee IJ, Seong J, Choi WH, Chung Y, Park SH

  • KMID: 2038086
  • Korean J Med Phys.
  • 2009 Sep;20(3):132-138.
Studies on target motion in 4-dimensional radiotherapy are being world-widely conducted to enhance treatment record and protection of normal organs. Prediction of tumor motion might be very useful and/or essential...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
A Study of Drug Content and Cell Cytotoxicity of Paclitaxel-eluting Stents Coated with Various Biopolymer

Kim DG, Shin IG, Kim GH, Kim SH, Lee JH, Ki BY, Nah JW, Suh TS, Kim SH

  • KMID: 2038085
  • Korean J Med Phys.
  • 2009 Sep;20(3):125-131.
In this study, the paclitaxel eluting stent (PES) was prepared by coating a biliary stent with paclitaxel using various biopolymer such as poly (vinyl acetate) (PVAc), poly (lactic-co-glycolic acid) (PLGA),...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close