Verification of the PMCEPT Monte Carlo dose Calculation Code for Simulations in Medical Physics

Kum O

  • KMID: 1482448
  • Korean J Med Phys.
  • 2008 Mar;19(1):21-34.
The parallel Monte Carlo electron and photon transport (PMCEPT) code [Kum and Lee, J. Korean Phys. Soc. 47, 716 (2006)] for calculating electron and photon beam doses has been developed...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Compare the Clinical Tissue Dose Distributions to the Derived from the Energy Spectrum of 15 MV X Rays Linear Accelerator by Using the Transmitted Dose of Lead Filter

Choi TJ, Kim JH, Kim OB

  • KMID: 1482455
  • Korean J Med Phys.
  • 2008 Mar;19(1):80-88.
Recent radiotherapy dose planning system (RTPS) generally adapted the kernel beam using the convolution method for computation of tissue dose. To get a depth and profile dose in a given...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Evaluation of Difference between Skin Motion and Tumor Motion for Respiration Gated Radiotherapy

Kwon KT, Lim S, Park SH, Kwon SI, Shin SS, Lee SW, Ahn SD, Kim JH, Choi EK

  • KMID: 1482447
  • Korean J Med Phys.
  • 2008 Mar;19(1):14-20.
Accounting for tumor motion in treatment planning and delivery is one of the most recent and significant challenges facing radiotherapy. The purpose of this study was to investigate the correlation...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
(99m)Tc Generator Safety Simulation Based on GEANT4

Kang SK, Han DH, Kim CY

  • KMID: 1482445
  • Korean J Med Phys.
  • 2008 Mar;19(1):1-8.
Technisium ((99m)Tc) is one of the most widely used radioactive isotopes for diagnosis in nuclear medicine. In general, technisium is produced inside the so called (99m)Tc generator which is usually...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Study on the Dose Characteristics of the PTW-LinaCheck Dosimeter and Its Application to Daily Output Measurement

Jeong DH, Lee KK, Moon UC, Kim HJ, Kim YS, Moon SR

  • KMID: 1482452
  • Korean J Med Phys.
  • 2008 Mar;19(1):56-62.
In this study, we have investigated the dose characteristics of PTW-LinaCheck designed to detect output of medical LINAC and discussed clinical use of the detector. The reproducibility, linearity, and dose...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Comparison of Skin dose Measurement Using Glass Dosimeter and Diode for Breast Cancer Patients

Ko YE, Park SH, Choi BJ, Kim HS, Noh YJ

  • KMID: 1482446
  • Korean J Med Phys.
  • 2008 Mar;19(1):9-13.
The purpose of this study was to measure the skin dose using the glass dosimeter and diode and to compare those measurements to the planned skin dose from the treatment...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Wireless Energy and Data Transmission Using Inductive Coupling

Lee JH

  • KMID: 1482450
  • Korean J Med Phys.
  • 2008 Mar;19(1):42-48.
Bio-implantable devices such as heart pacers, gastric pacers and drug-delivery systems require power for carrying out their intended functions. These devices are usually powered through a battery implanted with the...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Image Based Quality Assurance of Range Compensator for Proton Beam Therapy

Kim JS, Yoon M, Kim D, Lim YK, Kwak J, Park S, Shin DH, Shin J, Lee SB, Park SY, Cho KH

  • KMID: 1482449
  • Korean J Med Phys.
  • 2008 Mar;19(1):35-41.
The main benefit of proton therapy over photon beam radiotherapy is the absence of exit dose, which offers the opportunity for highly conformal dose distributions to target volume while simultaneously...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Comparison of Radiation Dose in the Measurement of MDCT Radiation Dose according to Correction of Temperatures and Pressure, and Calibration of Ionization Chamber

Lee CL, Kim HJ, Jeon SS, Cho HM, Nam S, Jung JY, Lee YJ, Lee SJ, Dong KR

  • KMID: 1482451
  • Korean J Med Phys.
  • 2008 Mar;19(1):49-55.
This study aims to conduct the comparative analysis of the radiation dose according to before and after the calibration of the ionization chamber used for measuring radiation dose in the...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Imaging Characteristics of Computed Radiography Systems

Jung J, Park HS, Cho HM, Lee CL, Nam S, Lee YJ, Kim HJ

  • KMID: 1482453
  • Korean J Med Phys.
  • 2008 Mar;19(1):63-72.
With recent advancement of the medical imaging systems and picture archiving and communication system (PACS), installation of digital radiography has been accelerated over past few years. Moreover, Computed Radiography (CR)...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Electrical Stimulation Parameters in Normal andDegenerate Rabbit Retina

Jin GH, Goo YS

  • KMID: 1482454
  • Korean J Med Phys.
  • 2008 Mar;19(1):73-79.
Retinal prosthesis is regarded as the most feasible method for the blind caused by retinal diseases such as retinitis pigmentosa (RP) or age related macular degeneration (AMD). Recently Korean consortium...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close