Annual Report on the External Quality Assessment Scheme for Routine Hematology in Korea (2017)

Lee YK, Kim YM

Under the Routine Hematology Program of the Korean Association of External Quality Assessment Service, complete blood count (CBC) and blood cell morphology proficiency tests were performed during 2017. We conducted...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Annual Report on the External Quality Assessment Scheme for Transfusion Medicine in Korea (2017)

Lim YA, Cho HS

Here, we have reported results of the surveys on the external quality assessment scheme (EQA) of the Transfusion Medicine Program (TMP) in Korea that were carried out in 2017. The...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Annual Report on the External Quality Assessment Scheme for Clinical Parasitology in Korea (2017)

Won EJ, Jung JS, Shin MG, Shin JH, Suh SP

Annual proficiency surveys were conducted in March, May, and August of 2017 as the Korean Association of External Quality Assessment Service. Overall, four image samples (MPI-17-01, MPI-17-02, MPI-17-03, MPI-17-04) in...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Usefulness of P(50,std) for the Diagnostic Work-up of Patients with Erythrocytosis

Shin SY

High oxygen-affinity hemoglobin (Hb) variants and a 2,3-diphosphoglycerate (2,3-DPG) deficiency could cause congenital (familial) erythrocytosis. High oxygen-affinity Hb variants and a 2,3-DPG deficiency might result in low tissue oxygen tension...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Establishing Reference Intervals for Complete Blood Cell Count in Healthy Korean Elderly Individuals

Lee EJ, Kim M, Lee E, Jeon K, Lee J, Kim HS, Kang HJ, Lee YK

BACKGROUND: Different age groups may have different reference intervals. However, the currently used reference interval for complete blood count (CBC) in clinical laboratories is based on results from healthy adults...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Performance Evaluation and Local International Sensitivity Index Verification Using Automated Coagulation Analyzer Coapresta 2000

Ham JY, Suh JS

BACKGROUND: The Coapresta 2000 (CP2000; Seikisui, Japan) system is a fully-automated random-access multiparameter coagulation analyzer equipped with a photo-optical clot detection unit. It can perform clotting time assays as well...
CITED
export Copy
Close
SHARE
Twitter Facebook